Download Digital Standard: TETRA Release 2

Transcript
TETRA Release 2
Remote Control Commands
Slot Configuration Settings
Parameters:
<SSlevel>
OFF | ATTenuated | FULL
OFF
Attenuation is maximum. The slot is inactive.
ATT
Level is reduced by the level attenuation set in "Slot Attenuation".
FULL
The level corresponds to the level indicated in the display.
*RST:
FULL
Example:
BB:TETR:LDIR UP
BB:TETR:CTYP CH11
Selects a control burst.
BB:TETR:SCON:TMOD1:SLOT3:LDIR2:SLEV FULL
BB:TETR:SCON:TMOD1:SLOT3:LDIR2:SSLevel FULL
Sets the level of the first and second sub-slot.
Manual operation:
See "(Sub-)Slot Level" on page 23
[:SOURce<hw>]:BB:TETRa:SCONfiguration:TMODe<di>:SLOT<st>:
LDIRection<ch>:TPATtern <TPattern>
Enters a user-defined TSC. The length of the training sequences depends on the burst
type. The first user bit is equivalent to the first bit of the training sequence. All further will
be inserted successively.
Parameters:
<TPattern>
integer
Example:
BB:TETR:SCON:TMOD1:SLOT2:LDIR1:TPAT
Manual operation:
See "TSC User Defined" on page 25
[:SOURce<hw>]:BB:TETRa:SCONfiguration:TMODe<di>:SLOT<st>:
LDIRection<ch>:TSOurce <TSource>
Determines whether the default or a user-defined training sequence (TSC) is used.
A user-defined training sequence can be created in the field "TSC User Defined".
Parameters:
<TSource>
DEFault | UDEFined
*RST:
DEFault
Example:
BB:TETR:SCON:TMOD1:SLOT2:LDIR1:TSO DEF
Manual operation:
See "Training Sequence" on page 25
User Manual 1175.6810.02 ─ 02
54