MOHAWK MODELS SYSTEM IA & SYSTEM IA-10
LIFT SPECIFICATIONS
SYSTEM IA & SYSTEM IA-10 SPECIFICATIONS
LIFT TYPE / TWO POST
LIFTING CAPACITY – SYSTEM IA
LIFTING CAPACITY – SYSTEM IA-10
PER ARM CAPACITY – SYSTEM IA
PER ARM CAPACITY – SYSTEM IA-10
LIFTING SPEED APPROX.
LIFTING HEIGHT
OVERALL WIDTH
WIDTH BETWEEN POST
WIDTH BETWEEN LIFTING ARMS
POST HEIGHT
OVERHEAD HYDRAULIC LINES
LIFTING PAD HEIGHT (MIN)
LIFTING PAD HEIGHT (MAX)
SHIPPING WEIGHT
SUGGESTED SITE SELECTION / BAY SIZE
WIDTH
15 FEET
ELEC/HYDRAULIC
9,000 LBS.
10,000 LBS.
2,250 LBS.
2,500 LBS.
45 SECONDS
72 INCHES
142-3/8 INCHES
120 INCHES
102 –7/8 INCHES
104 INCHES
144 INCHES
3-1/2 INCHES
75-1/2 INCHES
2,400 LBS.
HEIGHT
12 FEET
NOTE
THE PLACEMENT OF THE UNIT IS DETERMINED BY THE TYPE
(LENGTH, WIDTH, HEIGHT) OF VEHICLE BEING SERVICED.
WEJ-IT ANCHOR SPECIFICATIONS
LENGTH
DRILL
DEPTH
THRU
5 IN.
DRILL
SIZE
3/4 IN.
DRILL SIZE
MIN.
MAX.
.775 IN. .787 IN.
TORQUE
SEE
ANCHOR
SPECS
PRE-EXISTING FLOOR REQUIREMENTS
POWER UNIT SPECIFICATIONS
BRAND NAME
MODEL
POWER UNIT TYPE
MOTOR VOLTAGE
F.L.A. AT RATED CAPACITY
MOTOR HORSEPOWER
MOTOR PHASE
MOTOR CYCLE / HERTZ
MOTOR SPEED (R.P.M.)
PUMP FLOW (G.P.M.)
RELIEF VALVE SETTING
WORKING PRESSURE
RESERVOIR CAPACITY
HYDRAULIC FLUID MEDIUM
DEPTH
20 FEET
MONARCH
M-4509-0100
VERTICAL
208
/
230
13.9 /
13
2 1/2
SINGLE
60
3450
2.39 @ 3450 R.P.M.
2800 P.S.I.
2500 P.S.I.
2.5 GALLONS
DEXRON III
MINIMUM
THICKNESS
4 - 1/2 IN
MINIMUM COMPRESSIVE
STRENGTH
4000 P.S.I.
MINIMUM
AGING
28 DAYS
DO NOT INSTALL ANY MOHAWK LIFT ON ANY SURFACE OTHER
THAN
CONCRETE
CONFORMING
TO
THE
MINIMUM
COMPRESSIVE STRENGTH, MINIMUM AGING, AND THE
MINIMUM THICKNESS STATED ABOVE.
DO NOT INSTALL ANY MOHAWK LIFT ON EXPANSION SEAMS OR
ON CRACKED, OR DEFECTIVE CONCRETE.
DO NOT INSTALL ANY MOHAWK LIFT ON SECONDARY FLOOR
LEVELS OR ANY SURFACE WITH A BASEMENT BENEATH
WITHOUT WRITTEN AUTHORIZATION FROM THE BUILDING
ARCHITECT. NEVER HAND MIX YOUR OWN CONCRETE.
IF FOR ANY REASON A NEW CONCRETE SLAB SECTION IS
REQUIRED, FOLLOW THE INSTRUCTIONS FOR THE FLOOR
MODIFICATION DATA.
Load (LBS)
Performance Table
10000
9000
8000
7000
6000
5000
4000
3000
2000
1000
0
FLOOR MODIFICATION DATA
NEW FLOOR SECTION
THICKNESS
12 INCHES
SLAB SIZE
WIDTH X LENGTH
48 INCH x 161 INCH
CUBIC
YARDS
2.1
IF, FOR ANY REASON, A NEW CONCRETE SLAB SECTION IS
REQUIRED, MINIMUM THICKNESS, COMPRESSIVE STRENGTH,
AND PROPER AGING IS MANDATORY.
0
500
1000
1500
2000
THE NEW SLAB SECTION MUST BE TOTALLY SURROUNDED BY
AN EXISTING CONCRETE FLOOR THAT IS STRUCTURALLY
SOUND. CERTIFIED STRENGTH DOCUMENTATION SHOULD BE
OBTAINED FROM THE FIRM WHO SUPPLIES THE CONCRETE
MIXTURE AT THE TIME OF THE POUR.
2500
Pump Pressure (PSI)
NEVER HAND MIX THE CONCRETE. REFER TO NEW SLAB
RECOMMENDATIONS SECTION.
3