Transcript
II COMPONENT DESCRIPTIONS 2.3.5.2.1 DATATRAIN VIII Specific An optional parameter for the DATATRAIN VIII code system follows: The DATATRAIN VIII serial code type may require a specific one to four byte hexadecimal address which is specified after the optional SERIAL.FLAG parameter and before the OUTPUT keyword. Either a slave address and or a peer address may be declared. Defaults for slave and peer addresses are zero. If this parameter is specified the slave address is specified by using the keyword DT8.SLV.ADDRESS: followed by a variable length (1 to 4 byte) hexadecimal string which is preceded and followed by double quotes. It is also possible to specify the peer address by using the keyword DT8.PEER.ADDRESS: followed by a variable length (1 to 4 byte) hexadecimal string which is preceded and followed by double quotes. 2.3.5.2.2 ALLEN BRADLEY DF1 Specific An optional parameter for the DF1 code system follows: The DF1 serial code type may require a specific control and indication byte offset which is specified after the optional SERIAL.FLAG parameter and before the OUTPUT keyword. Either a control offset and or a indication offset may be declared. Defaults for control and indication offsets are zero. If this parameter is specified the control offset is specified by using the keyword CONTROL.OFFSET: followed by an integer value in the range of 0-99 bytes. It is also possible to specify the indication offset by using the keyword IND.OFFSET: followed by an integer value in the range of 0-99 bytes. 2.3.5.3 OUTPUT Declaration The OUTPUT declaration immediately follows the ADDRESS declaration if outputs are to be defined. The OUTPUT declaration is not required. Following the OUTPUT declaration is a list of bits which are to be sent to the Master. The list may contain 1 to 256 bit names separated by commas and terminated by a semicolon. (The upper limit of 256 bits applies to GENISYS protocol Slaves. The limit for other Serial Slave types may be lower.) 2.3.5.4 INPUT Declaration INPUT declaration immediately follows the OUTPUT declaration or the ADDRESS declaration if the OUTPUT declaration is not present. Following the INPUT declaration is a list of bits which are expected to be received by the Slave. The list may contain 1 to 256 bit names separated by commas and terminated by a semicolon. (The upper limit of 256 bits applies to GENISYS protocol Slaves. The limit for other Serial Slave types may be lower.) 2.3.6 ATCS.SLAVE or ARES.SLAVE The ATCS.SLAVE or ARES.SLAVE section defines the input/output interface for the GENISYS 2000 AxxS Slave communication port. This declaration is valid only in application programs to be used with GENISYS 2000 AxxS Slave protocol Executive. Up to 6 AxxS “logical Slaves” can be supported by a single GENISYS 2000 unit although only one is normally defined. The “xx” refers to ATCS or ARES Slave types; ATCS and ARES may not be mixed. In future releases, various ATCS/ARES slave types may be declared immediately following the AxxS.SLAVE keyword. Presently, the ARES slave type is “ARES” and the ATCS slave type is “ATCS”. This optional parameter will follow the same syntax as SERIAL.SLAVE and DC.SLAVE. Any mixing of these two Slave types will result in a compiler error. (See section 2.3.5, SERIAL.SLAVE for additional discussion on the definition of multiple logical Slaves.) 2-14 SM 6700A 8/96