APPENDIX B CALIBRATION CALIBRATION Introduction This appendix provides tips for calibrating the PlateStream. Following these procedures will provide the best results, especially when printing screens. Calibration has two major steps: I. Setting maximum density (Dmax) in solid black areas by adjusting the laser power. II. Linearization of the dot percentage transfer curve by calibrating the RIP. PlateStream users doing critical screens have found it helpful to calibrate the platesetter weekly(or more often if required) and replace the processing chemistry every two weeks (or more often if required). I. Setting Maximum Density Before calibrating dot density, maximum density (Dmax) is set by adjusting laser power from the PlateStream operator panel. There are several ways to do this: A. Using an exposure file: 1. 2. 3. 4. From the RIP, run file 805346-1.ps using the lowest resolution that your PlateStream is set up for (i.e. 900 or 1200 DPI). Use a page setup from the RIP that corresponds to this lowest resolution. With the unaided eye, look at the 1x1, 2x2, 3x3, 4x4, and 8x8 checkerboard patterns. If all 5 patterns look the same density the same grey level the image power is correct. If the patterns get lighter grey going from 8x8 to 1x1 with 1x1 being the lightest, the image power is set too low. Increase the image power and run the file again. Again look at the patterns to determine if the grey level is acceptable. (This image power is made from the op panel main menu as follows: #1) Setup, enter. (Verify that the resolution shown after #2) is the same as you ran the file at). #3) Image Power (type in a higher (or lower) image power setting number), enter. Then re-run the file. B-2