Download APPLICATORS - Ransburg.com

Transcript
Ranflex Applicators - INSTALLATION
2. All objects inside spray area must be grounded reference EN 50 176 and/or NFPA-33. Resistance
to earth ground must be less than 1 meg Ohm.
2. Turn off power.
3. Flammable liquids must be contained in approved
metalic grounded containers.
3. Connect fluid hose.
Interlocks Required
Interlock the solvent supply with the main supply air
to the applicator. When solvent is On, main supply air
to the applicator is Off. Interlocks are user supplied.
! WARNING
4. Connect air.
†† The solvent supply must be interlocked
with applicator supply air.
INSTALLATION
1. Ensure there is a true earth ground connection
available. Connect the fluid source and air hose
ground to this connection.
! WARNING
†† Both the fluid source and the air hose ground
must be connected to true earth ground.
OR...
5. Trigger applicator with fluid off. Look for leaks in
any connections
6. Activate fluid, check for leaks with solvent flush if
required.
AH-15-01.2
Return To Contents
20