Download APPLICATORS - Ransburg.com
Transcript
Ranflex Applicators - INSTALLATION 2. All objects inside spray area must be grounded reference EN 50 176 and/or NFPA-33. Resistance to earth ground must be less than 1 meg Ohm. 2. Turn off power. 3. Flammable liquids must be contained in approved metalic grounded containers. 3. Connect fluid hose. Interlocks Required Interlock the solvent supply with the main supply air to the applicator. When solvent is On, main supply air to the applicator is Off. Interlocks are user supplied. ! WARNING 4. Connect air. The solvent supply must be interlocked with applicator supply air. INSTALLATION 1. Ensure there is a true earth ground connection available. Connect the fluid source and air hose ground to this connection. ! WARNING Both the fluid source and the air hose ground must be connected to true earth ground. OR... 5. Trigger applicator with fluid off. Look for leaks in any connections 6. Activate fluid, check for leaks with solvent flush if required. AH-15-01.2 Return To Contents 20