Download EX360 Service Manual - Red-D
Transcript
PRE-POWER CHECKS 6-3. Measuring Input Capacitor Voltage Y Turn Off welding power source, and disconnect input power. Remove cover 5 Power Interconnect Board PC2 2 Voltmeter 3 Capacitor C12 Measure the dc voltage across C12 (+) Positive Terminal and C12 (−) Negative Terminal on PC2 as shown until voltage drops to near 0 (zero) volts. Typical Bleeder Resistor 25 to 1000 ohm, 5 watt resistor 1 Y Significant DC voltage can remain on capacitors after unit is Off. Always check the voltage as shown to be sure the input capacitors have discharged before working on unit. 4 Capacitor C13 Measure the dc voltage across C13 (+) Positive Terminal and C13 (−) Negative Terminal on PC2 as shown until voltage drops to near 0 (zero) volts. . If the capacitor voltage does not #16 AWG 1000 volts dc insulation rating, approx. 3 in (76 mm) leads drop to near zero after several minutes, use a bleeder resistor of between 25 and 1000 ohms, at least 5 watts, #16 AWG 1000 volts dc insulating rating wire to discharge the capacitor(s) . 5 Typical Bleeder Resistor An example of a typical bleeder resistor is shown on this page. Proceed with pre-power flowchart. 4 1 2 3 1 2 Positive (+) lead to C13 (+) terminal, Negative (−) lead to C13 (−) terminal Positive (+) lead to C12 (+) terminal, Negative (−) lead to C12 (−) terminal Test Equipment Needed: Ref. 803 721-B / 907 161 Extreme 360 TM-229 409 Page 19