Download EX360 Service Manual - Red-D

Transcript
PRE-POWER CHECKS
6-3. Measuring Input Capacitor Voltage
Y Turn Off welding power
source, and disconnect input
power.
Remove cover
5
Power Interconnect Board
PC2
2
Voltmeter
3
Capacitor C12
Measure the dc voltage across
C12 (+) Positive Terminal and C12
(−) Negative Terminal on PC2 as
shown until voltage drops to near
0 (zero) volts.
Typical Bleeder Resistor
25 to 1000 ohm,
5 watt resistor
1
Y Significant DC voltage can
remain on capacitors after
unit is Off. Always check the
voltage as shown to be sure
the input capacitors have discharged before working on
unit.
4
Capacitor C13
Measure the dc voltage across
C13 (+) Positive Terminal and C13
(−) Negative Terminal on PC2 as
shown until voltage drops to near
0 (zero) volts.
. If the capacitor voltage does not
#16 AWG 1000 volts dc
insulation rating, approx.
3 in (76 mm) leads
drop to near zero after several
minutes, use a bleeder resistor
of between 25 and 1000 ohms,
at least 5 watts, #16 AWG 1000
volts dc insulating rating wire to
discharge the capacitor(s) .
5
Typical Bleeder Resistor
An example of a typical bleeder resistor is shown on this page.
Proceed with pre-power flowchart.
4
1
2
3
1
2
Positive (+) lead to C13 (+) terminal,
Negative (−) lead to C13 (−) terminal
Positive (+) lead to C12 (+) terminal,
Negative (−) lead to C12 (−) terminal
Test Equipment Needed:
Ref. 803 721-B / 907 161
Extreme 360
TM-229 409 Page 19