Communication demand capacity 0~255
38
51
50
49
48
47
46
Fan
2
00001100
4
"Min.Sj correction
depends on Td"
State of compressor frequency(Hz) control (Words)
Discharge pressure control
Compressor temperature control
SV control
Abnormal rise of Pd control
Heat Sink over heat prevention control
Secondary current control
Input current contol
Hz correction of receipt voltage decrease prevention
Hz restrain of receipt voltage change
"Freeze
prevention
control"
8
Low pressure decrease
SHd control
prevention
Frozen
"Power module
TH6 abnormality
protection
abnormality"
Content
Hz control by pressure limitation
Hz control by discharge temperature limitation
Hz control by bypass valve
Control that restrains abnormal rise of discharge pressure
Heat Sink over heat prevention control
Secondary current control
Input current contol
Max.Hz correction control due to voltage decrease
Max.Hz correction control due to receipt voltage change
"Frequency restrain of
receipt voltage change"
4-way valve disconnection
abnormality
Pd abnormality Pd Back up
control (heating) (heating)
Discharge temp.
(heating) backup
3-min.delay/no
"LEV opening correction "LEV opening correction "Correction of high compression
depends on Pd"
depends on Td"
ratio prevention"
Refrigerant pull back/no Excitation current/no
"P93:Silent
CN3D1-2 input"
7
"Min.Sj correction
depends on Shd"
DEFROST/NO
P94:Demand
CN3D1-3 input
6
"Heating thermo-ON" "Heating thermo-OFF"
5
Display on the LED1, 2 (display data)
"Cooling thermo-ON" "Cooling thermo-OFF"
3
"State of compressor "Heat Sink over heat
"Secondary
"Input current
frequency control 2" prevention control"
current control" control"
63LS
10001100 Protection input
HIC abnormality
abnormality
"The second current value when
0~999.9[Arms]
microprocessor of POWER
01001100
BOARD abnormality is detected"
"The radiator panel temperature
when microprocessor of POWER
-99.9~999.9 (Short/Open:-99.9 or 999.9)
11001100
BOARD
abnormality is detected"
0000~9999 (unit: x10)
0~999.9 (A)
0~999.9 (A)
0000~9999 (unit: x10)
0~255
0~255
0~999.9 (V)
"Td over heat
"SHd decrease
01110100
State of LEV control
prevention"
prevention"
Compressor
"State of compressor Discharge
temperature
11110100
frequency control 1" pressure control control
39 11100100 Number of compressor ON/OFF
40 00010100 Compressor operating current
41 10010100 Input current of outdoor unit
42 01010100 Thermo-ON operating time
43 11010100 Total capacity of thermo-ON
44 00110100 Number of indoor units
45 10110100 DC bus voltage
01100100
External connection status
37 10100100
1
ON/OFF
Heating/Cooling Abnormal/normal
P97:Autochange over
P96:Autochange over fixed P95:Undefined
CN3S1-2 input
permission CN3N1-3 input mode CN3N1-2 input
OFF
IC1 operation mode
IC2 operation mode
IC3 operation mode
IC4 operation mode
IC5 operation mode
OC operation mode
31
32
33
34
35
36
Display mode
SW1
setting
12345678
11111000
00000100
10000100
01000100
11000100
00100100
No.
Light on/light off
Input: light off No input: light
on
display of communication
demand capacity
•Display of indoor unit operating mode
Notes