Download V160-S & -T
Transcript
THEORY OF OPERATION Return to Master TOC Return to Section TOC EE-5 EE-5 FIGURE EE.5 – DISPLAY BOARD S1 115/230/1/50/60 Vac WHITE 2 1 BLUE BLACK 4 3 BROWN RED DC+ AC1 DC+ W1 + W2 - BLACK DC-A AC2 DC- INVERTER BOARD W05X0190 (SCHEMATIC X0190) Y/G GREEN GND INPUT BOARD W05X0250 GND JP1 (SCHEMATIC X0203) FAN 1 2 3 4 5 6 7 8 9 10 1 2 JP2 3 6 JP1 DCW1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Return to Master TOC Return to Section TOC 26 25 24 23 22 21 20 19 18 17 16 15 14 13 12 11 DISPLAY BOARD W05X0245 10 9 8 7 6 5 4 3 2 1 J1 (SCHEMATIC X0245) METER BOARD W05X0207 (SCHEMATIC X0207) WELD CONTROLLER W05X0233 (SCHEMATIC X0233) JP1 1 WARNING HIGH VOLTAGE CAN KILL • Do not operate with coers removed. • Disconnect input power by unplugging power cord before servicing. • Do not touch electrically live parts. • Only qualified persons should install, use or service this machine 2 D 3 4 E 5 6 7 8 C B A REMOTE CONNECTOR CW Return to Master TOC Return to Section TOC DISPLAY BOARD The display board receives status and analog signals from the inverter board and various sensors. It is composed of 2 parts: - Weld controller: Interprets signals, makes decisions and changes the machine mode and output to satisfy the requirements as dictated by the operator. - Display board: Supports all the potentiometer, switches and LED Return to Master TOC Return to Section TOC - Meter board: Displays the pre-set and actual output current NOTE: Unshaded areas of Block Logic Diagram are the subject of discussion V160-S & -T