4-2 Electrical Malfunction
(Continued)
RF radiant element
(No heating or
Abnormal working)
END
*Tighted terminal of harness by
compressing not to be loosen.
*check the element of RF Radiant
Yes
*Check whether harness connected
wire and the state of RF infinite
switch are in normal.
*Check whether harness in
terminal of Radiant has
been loosen or disconnected.
No
Yes
Yes
*Weld with terminal not to be misconnected
if harness is disconnected from terminal
on Radiant.
END
Assembly RF Cooktop
WARNING
“B”
“A”
2a
It is very dangerous when radiant heater is
working in case that harness has misconnected.
Fig.6 LR radiant element
2b
1b
Yes
Position
ohms
1b-2b
2a-"A"
45~55Ω
2a-"B"
42~48Ω
∞
(at the room temperature)
*Check whether harness is connected with
RF infinite switch has been damaged or
disconnected.
Fig.7 The drawer of connected wire of harness
Position
"A"
"B"
1b
2a
2b
END
47
Color
Blue
Orange
Brown
Black
Violet + Violet