Download EXLAR Corporation
Transcript
3.4 Roller Screw The planetary roller screw used within the I Series actuators is a precision mechanism. The standard actuator will be supplied lubricated and sealed from the factory. Lubrication of the roller screw should be maintained in accordance with section 2.3. Shock load and radial load should be avoided to provide maximum life from the actuator. Extending or retracting the roller screw into the ends of travel may cause damage to the actuator or the other components of the application. For roller screw life calculations and specifications see section 5.0. 3.5 End Of Stroke Cushions Every standard I Series actuator is equipped with nitrile rubber impact bumpers, which are designed to protect the actuator from accidental over extension or retraction. End of stroke cushions are provided for fail safe only and should not be used as an application limit of stroke. I-Series Actuators are designed with an additional 0.4” (10.16 mm) of length over nominal stroke. This is to allow users to utilize the full nominal stroke without causing damage by end crashing. See figures 10-1 to 10-3 for information on stroke limits and how to position limit switches. Figure 10-1: Actuator Shown in fully retracted “crash” position, with contact on forward impact bumper I Series Manual. PN: 27667 Rev.Q Page 19 11/12/14 Curtiss-Wright 952-500-6200