JEMStar User Manual JEMSTAR SERVICING JEMStar meters are available in socket-base (S- and A-base), and switchboard mounting packages. The disassembly procedure for each type is described as follows. Socket-base meters (S- and A-base) Globe Removal 1. Remove power from meter! 2. Remove all wire seals from the locking ring of the meter globe, and then remove the ring. You do NOT need to remove any seals from the RESET button. 3. Turn the globe counter-clockwise approximately 1 inch to disengage it from the base. 4. Carefully slide the globe forward away from the base and set it aside. Internal Housing Disassembly 1. Remove the top cover of the housing by unscrewing three Phillips-head screws (below). Carefully lift the cover off, paying particular attention to the RAM battery wires. Do not unplug the battery, or data will be lost! Top View of meter with globe removed Remove screws at these locations, then lift the top cover off. Be careful of the battery wires! 88