Heurikon HK68/M120 - User's Manual
MULTIBUS CONTROL
40
~
40
Using Swap convention (Intel style) precludes running 68020 programs
that use Multibus memory. Although character streams will be correct
in either word or byte mode, the MPU will get confused after writing
a word numeric value to memory and trying to read one byte of that
word. It will always read the wrong byte. For example, the MPU will
read the LSB when the software expects the MSB. Intel style should
only be used when it is necessary to communicate with an Intel-based
intelligent device and no Multibus memory is required for the program
running on the HK68/M120.
The charts on at the end of this section can be used to determine how
various system configurations will operate. Don't spend too much time
trying to understand the bus data conventions unless you have a specific
need; it is definitely headache material.
All MPU generated Multibus byte operations are conducted on the lower
eight Multibus data lines, with DAT7/ being the most significant bit. For
word transfers, DATF / .!!. the ~ significant bit, as per the Multibus
specification. Caution: Some Multibus I vendors always put the MSB on
DAT7/, even for 16=bit transfers!
11.7
Watchdog Timer
The HK68/M120 has a timer which monitors board activity. If the timer is
enabled and if the on-card physical address strobe stays on for
approximately one millisecond, the timer will expire. This will cause the
current memory cycle to be terminated. The timer is disabled by setting
DID of the Memory Control Word to one.
See section 9.1 for more details on the watchdog timer.
11.8
Mailbox
The HK68/M120 mailbox logic generates a MPU interrupt if a Multibus access
is detected within a certain address range.
The address range is
specified by the contents of the bus map PLE (U80). The interrupt is
generated by the CIO. Jumper J19 is used to enable/disable the mailbox
logic (install to enable).
The bus map PLE sets the base and size of the mailbox address range.
Usually, the mailbox size is only 64K bytes, which is the smallest range
possible. One general purpose PLE, part number M120-MAP-DO, is detailed
below. Other variations may be available; please consult the factory.