Download Yokogawa UT75A Digital Indicating Controller Data

Transcript
11
<<Contents>> <<Index>>
E4-terminal area E1-terminal area
101
-112
501
-512
401
-412
301
-312
201
-212
101
501
401
301
201
102
502
302
202
103
503
303
203
104
504
304
204
105
505
305
205
106
506
306
206
107
507
407
307
207
108
508
408
308
208
109
509
409
309
209
110
510
410
310
210
111
511
411
311
211
112
512
412
312
212
E1-Terminal Area
301-306
307-312
(Suffix code: Type 1=-5)
PV2 input
(Suffix code: Type 2=0 or 1)
Contact output DO
PV2
TC input
E2-Terminal Area
RTD input
External contact output
A 201
+ 202
Factory default: No function
b 202
- 203
Factory default: No function
B 203
UT
DO25 307
DO24 308
Factory default: No function DO23 309
Current (mA) input Voltage (mV, V) input
Factory default: No function DO22 310
- 203
+ 202
+ 204
- 203
Factory default: No function DO21 311
COM 312
Common
Transistor contact rating: 24 V DC, 50 mA
E3-terminal area
Function can be assigned
to the terminals with no
function.
(Suffix code: Type 2=2)
Aux. analog input / Contact input AIN2
E2-terminal area
External contact input
No-voltage contact
UT
Contact rating: 12 V DC, 10 mA or more
Aux. analog input
Specify within a
range of 1-5 V DC,
0-2 V DC,0-10 V DC
309
310
310 DI26
Factory default: No function
UT
Transistor contact
309 COM
Common
COM
DI26
+5V
Function can be assigned
to the terminals with no
function.
+ 311
- 312
Default: 1-5 V DC
Aux. analog input can be used for
feedforward input in Single-loop control and
Single-loop position proportional control.
E3-Terminal Area
401-412
PROFIBUS-DP communication (with Modbus master)
RS-485 communication/Contact input
SDA(-)
SG
1
(Suffix code: Type 3=1)
2
2
RDY
3
3
RDB(+) 4
RDA(-) 5
UT
No-voltage contact
Transistor contact
407
408 DI31
408
Factory default: No function
409 DI32
409
Factory default: No function
410 DI33
410
Factory default: No function
411 DI34
411
Factory default: No function
412 DI35
412
COM
DI31
DI32
DI33
DI34
DI35
UT
+5V
+5V
+5V
+5V
+5V
Function can be assigned to the
terminals with no function.
Contact rating: 12 V DC, 10 mA or more
Ethernet communication (with gateway function)
ETHR
10BASE-T/100BASE-TX
RJ45 connector
(Suffix code: Type 3=2)
390Ω
Color
Amber
Lit
100M bps
Unlit
10M bps
Green
Lit
Linked
Blink
Active
Unlit
Link failure
+5V bus power
RxD/TxD-P
Data signal
(positive data receive/transmit)
3
RxD/TxD-N
Data signal
(negative data recive/transmit)
4
DGND
Signal ground
5
SHIELD
LED
CHK
(red)
RSB(+) 407
SG
409
CC-L
DA
CHK
(Suffix code: Type 3=3)
110Ω
DB
L ERR
CHK
Description
FG
Frame ground
2
SLD
Shield
3
DG
RX/TX signal ground
DB
5
DA
LED
CHK
(red)
RSA(-) 408
Transistor contact
501
Factory default: No function
502 DI41
Factory default: No function
503 DI42
503
Factory default: No function
504 DI43
504
Factory default: No function
505 DI44
505
Factory default: No function
506 DI45
506
COM
502
Contact rating: 12 V DC, 10 mA or more
DI41
DI42
DI43
DI44
DI45
UT
+5V
+5V
+5V
+5V
+5V
Function can be assigned to the
terminals with no function.
RS-485
409
1
V+
Description
DeviceNet power supply 24V
2
CAN_H
RX/TX + signal
3
DRAIN
Shield/Drain wire
4
CAN_L
RX/TX - signal
Aux. analog input
RSB(+)
501
RSA(-)
502
SG
503
+ 505
- 506
External contact input
(Suffix code: Type 3=5)
If the UP is located at the
end of a segment for the
DeviceNet
communication wiring,
terminating resistors are
separately needed.
These are to be
prepared by users. (121
Ω: 1 pc.)
Specify within a
range of 1-5 V DC,
0-2 V DC,0-10 V DC
Default: 1-5 V DC
DNET
CAN_L
MNS
V-
UT
501 COM
AIN4/RS485 (Suffix code: Type 2=1 or 2)
RS-485 communication / Remote input / Contact input
RSB(+) 407
SG
Normal
121Ω
2
External contact input
No-voltage contact
Common
No-voltage contact
Common
REMOTE when DI46=ON
LOCAL when DI46=OFF
UT
Transistor contact
503 COM
503
504 DI46
504
COM
DI46
UT
+5V
Contact rating: 12 V DC, 10m A or more
DeviceNet power supply common
Lit/flashing
User profile error
Normal. Communicating
successfully (green, lit).
Not connected (green, flashing).
MNS Critical link failure (red, lit).
(green/ Communication timeout (red,
red) flashing)
At power-on/Communication
faulted (green/red, flashing)
Unlit
Normal
RS-485
RSB(+) 407
No electricity
RSA(-) 408
SG
409
If the UT is located at
the end of a segment
for the CC-Link
communication wiring,
terminating resistors
are separately needed.
These are to be
prepared by users.
(110 Ω: 1 pc.)
L RUN
1
Normal
No power, or
Communication
failure
1
CHK
(red)
4
Not connected, or
communication
failure (flashing)
DI (Suffix code: Type 2=0)
RS-485
CAN_H
5
CC-Link communication (with Modbus master)
If the UT is located at
the end of a segment
for the PROFIBUS
communication wiring,
terminating resistors
are separately
needed.
These are to be
prepared by users.
(390 Ω: 2 pcs. 220 Ω:
1 pc., or an active
terminator.)
DeviceNet communication (with Modbus master)
LED
5
User profile error
ERR
(red)
(Suffix code: Type 3=4)
Unlit
RDY Normal
(green) Communicating
successfully
Pin Signal name
RSA(-) 408
Pin Signal name
Shield ground
Lit
5
Lower side LED (link activity)
Color
VP
2
4
RS-485
Description
1
3
Upper side LED (baud rate)
4
RxD/TxD-N
DGND
Pin Signal name
407 COM
Factory default: No function
3
Data
5
Common
2
RxD/TxD-P
220Ω
ERR line
4
External contact input
1
390Ω
Data
CHK line
Contact input
PROF
VP
RS485/DI
SDB(+) 1
E4-Terminal Area
501-506
RX/TX - signal
RX/TX + signal
Lit
User profile error/
Address error
L ERR Communication failure
(red) (CRC error)
Unlit
Normal
Normal
No carrier
L RUN Normal
detected/
(green) Communicating successfully Connection
timeout
RS-485
RSB(+) 407
RSA(-) 408
SG
409
All Rights Reserved. Copyright © 2013, Yokogawa Electric Corporation
Subject to change without notice.
GS 05P01B41-01EN
Feb. 08, 2013-00