Download Yokogawa UT75A Digital Indicating Controller Data
Transcript
11 <<Contents>> <<Index>> E4-terminal area E1-terminal area 101 -112 501 -512 401 -412 301 -312 201 -212 101 501 401 301 201 102 502 302 202 103 503 303 203 104 504 304 204 105 505 305 205 106 506 306 206 107 507 407 307 207 108 508 408 308 208 109 509 409 309 209 110 510 410 310 210 111 511 411 311 211 112 512 412 312 212 E1-Terminal Area 301-306 307-312 (Suffix code: Type 1=-5) PV2 input (Suffix code: Type 2=0 or 1) Contact output DO PV2 TC input E2-Terminal Area RTD input External contact output A 201 + 202 Factory default: No function b 202 - 203 Factory default: No function B 203 UT DO25 307 DO24 308 Factory default: No function DO23 309 Current (mA) input Voltage (mV, V) input Factory default: No function DO22 310 - 203 + 202 + 204 - 203 Factory default: No function DO21 311 COM 312 Common Transistor contact rating: 24 V DC, 50 mA E3-terminal area Function can be assigned to the terminals with no function. (Suffix code: Type 2=2) Aux. analog input / Contact input AIN2 E2-terminal area External contact input No-voltage contact UT Contact rating: 12 V DC, 10 mA or more Aux. analog input Specify within a range of 1-5 V DC, 0-2 V DC,0-10 V DC 309 310 310 DI26 Factory default: No function UT Transistor contact 309 COM Common COM DI26 +5V Function can be assigned to the terminals with no function. + 311 - 312 Default: 1-5 V DC Aux. analog input can be used for feedforward input in Single-loop control and Single-loop position proportional control. E3-Terminal Area 401-412 PROFIBUS-DP communication (with Modbus master) RS-485 communication/Contact input SDA(-) SG 1 (Suffix code: Type 3=1) 2 2 RDY 3 3 RDB(+) 4 RDA(-) 5 UT No-voltage contact Transistor contact 407 408 DI31 408 Factory default: No function 409 DI32 409 Factory default: No function 410 DI33 410 Factory default: No function 411 DI34 411 Factory default: No function 412 DI35 412 COM DI31 DI32 DI33 DI34 DI35 UT +5V +5V +5V +5V +5V Function can be assigned to the terminals with no function. Contact rating: 12 V DC, 10 mA or more Ethernet communication (with gateway function) ETHR 10BASE-T/100BASE-TX RJ45 connector (Suffix code: Type 3=2) 390Ω Color Amber Lit 100M bps Unlit 10M bps Green Lit Linked Blink Active Unlit Link failure +5V bus power RxD/TxD-P Data signal (positive data receive/transmit) 3 RxD/TxD-N Data signal (negative data recive/transmit) 4 DGND Signal ground 5 SHIELD LED CHK (red) RSB(+) 407 SG 409 CC-L DA CHK (Suffix code: Type 3=3) 110Ω DB L ERR CHK Description FG Frame ground 2 SLD Shield 3 DG RX/TX signal ground DB 5 DA LED CHK (red) RSA(-) 408 Transistor contact 501 Factory default: No function 502 DI41 Factory default: No function 503 DI42 503 Factory default: No function 504 DI43 504 Factory default: No function 505 DI44 505 Factory default: No function 506 DI45 506 COM 502 Contact rating: 12 V DC, 10 mA or more DI41 DI42 DI43 DI44 DI45 UT +5V +5V +5V +5V +5V Function can be assigned to the terminals with no function. RS-485 409 1 V+ Description DeviceNet power supply 24V 2 CAN_H RX/TX + signal 3 DRAIN Shield/Drain wire 4 CAN_L RX/TX - signal Aux. analog input RSB(+) 501 RSA(-) 502 SG 503 + 505 - 506 External contact input (Suffix code: Type 3=5) If the UP is located at the end of a segment for the DeviceNet communication wiring, terminating resistors are separately needed. These are to be prepared by users. (121 Ω: 1 pc.) Specify within a range of 1-5 V DC, 0-2 V DC,0-10 V DC Default: 1-5 V DC DNET CAN_L MNS V- UT 501 COM AIN4/RS485 (Suffix code: Type 2=1 or 2) RS-485 communication / Remote input / Contact input RSB(+) 407 SG Normal 121Ω 2 External contact input No-voltage contact Common No-voltage contact Common REMOTE when DI46=ON LOCAL when DI46=OFF UT Transistor contact 503 COM 503 504 DI46 504 COM DI46 UT +5V Contact rating: 12 V DC, 10m A or more DeviceNet power supply common Lit/flashing User profile error Normal. Communicating successfully (green, lit). Not connected (green, flashing). MNS Critical link failure (red, lit). (green/ Communication timeout (red, red) flashing) At power-on/Communication faulted (green/red, flashing) Unlit Normal RS-485 RSB(+) 407 No electricity RSA(-) 408 SG 409 If the UT is located at the end of a segment for the CC-Link communication wiring, terminating resistors are separately needed. These are to be prepared by users. (110 Ω: 1 pc.) L RUN 1 Normal No power, or Communication failure 1 CHK (red) 4 Not connected, or communication failure (flashing) DI (Suffix code: Type 2=0) RS-485 CAN_H 5 CC-Link communication (with Modbus master) If the UT is located at the end of a segment for the PROFIBUS communication wiring, terminating resistors are separately needed. These are to be prepared by users. (390 Ω: 2 pcs. 220 Ω: 1 pc., or an active terminator.) DeviceNet communication (with Modbus master) LED 5 User profile error ERR (red) (Suffix code: Type 3=4) Unlit RDY Normal (green) Communicating successfully Pin Signal name RSA(-) 408 Pin Signal name Shield ground Lit 5 Lower side LED (link activity) Color VP 2 4 RS-485 Description 1 3 Upper side LED (baud rate) 4 RxD/TxD-N DGND Pin Signal name 407 COM Factory default: No function 3 Data 5 Common 2 RxD/TxD-P 220Ω ERR line 4 External contact input 1 390Ω Data CHK line Contact input PROF VP RS485/DI SDB(+) 1 E4-Terminal Area 501-506 RX/TX - signal RX/TX + signal Lit User profile error/ Address error L ERR Communication failure (red) (CRC error) Unlit Normal Normal No carrier L RUN Normal detected/ (green) Communicating successfully Connection timeout RS-485 RSB(+) 407 RSA(-) 408 SG 409 All Rights Reserved. Copyright © 2013, Yokogawa Electric Corporation Subject to change without notice. GS 05P01B41-01EN Feb. 08, 2013-00