5. Parameters
5-25
5-26
MOSCON-E7 User’s Manual
5.5.3 Dwell operation
5.5.4 Energy saving operation
5.5.3.1 Controlling the dwell operation : S2.01~S2.04
Energy can be saved by decreasing the output voltage of the inverter in
steady-state under a light load condition.
Do not use the energy-saving function in normal situation.
Parameter
No.
Name
Unit
Setting
range
Factory
Setting
S2.01
Dwell Frequency
at Start
Dwell Time
at Start
Dwell Frequency
at Stop
Dwell Time
at Stop
0.01Hz
0.00
~600.0
0.00
~25.00
0.00
~600.0
0.00
~25.00
Changeable
during
operation
0.00
X
0.00
X
Parameter
No.
Name
Unit
Setting range
Factory
Setting
Changeable
during
operation
0.00
X
S3.01
Energy Saving
Voltage Level
1%
0~100
80
X
0.00
X
S2.02
S2.03
S2.04
0.01Sec
0.01Hz
0.01Sec
• Dwell function is used to temporarily hold the output frequency when
starting and stopping a motor with heavy load.
5.5.4.1 Setting the energy saving level : S3.01
• If S3.01=80, the output voltage in energy saving mode will be 80% of
the previous value.
5.5.4.2 Setting the energy-saving frequency : S3.02
Run Command
ON
Parameter
No.
OFF
S3.02
Output
Frequency
S2.01
S2.02
S2.03
Time
S2.04
Figure 5.10 Timing chart for dwell operation
Name
Unit
Energy Saving
0.01Hz
Frequency
Level
Setting range
Factory
Setting
Changeable
during
operation
0.00
~600.0
0.00
X
• S3.02 sets the minimum frequency for the effective energy saving
operation
• Energy-saving command is enabled when output frequency is higher
than the energy-saving frequency and motor speed is within the “speed
match” range or energy saving command is triggered from a external
input terminal.