Download AM/AB-800GE Manual
Transcript
AM-800GE / AB-800GE TriggerSelector Frame Start Operation ExposureMode OFF Timed TriggerWidth Previous JAI trigger name (for reference) Trig OFF(Free run) No Exposure Control Trigger OFF OFF Trig OFF(Free run) Exposure Control Is possible Trigger OFF ON Trig On EPS Trig OFF(Free run) No Exposure Control Trig On Trigger OFF PWC OFF or ON OFF ON FrameStart trigger: Set whether the start of the frame is to be controlled externally or not. TriggerMode On: While AcquisitionActive is effective and ExposureMode is set at Timed or TriggerWidth, start exposure using the signal selected by FrameStart trigger. TriggerMode Off: While AcquisitionActive is effective, self-running operation takes place. 9.2.1.3 Stream control The signal readout from the CCD can be stored in the frame memory and the stream control determines the timing of the readout as the stream. This can be compared to delayed readout in the previous model. ◆ JAI Acquisition Transfer Start: Trigger Mode ON : Set the start of the stream externally. When AcquisitionActive is active, the stream is output by JAI Acquisition Transfer Start. If AcquisitionActive is active status, the stream can be output. Trigger Mode OFF: 9.2.2 Triggersoftware This is one of the trigger sources and is the software trigger command. This has one command signal to each of the 6 items of TriggerSelector. To use this function, TriggerSource must be set at TriggerSoftware. 9.2.3 Triggersource The following signals can be selected as the trigger signal source. - 47 -