Download AM/AB-800GE Manual

Transcript
AM-800GE / AB-800GE
TriggerSelector
Frame
Start
Operation
ExposureMode
OFF
Timed
TriggerWidth
Previous JAI
trigger name
(for reference)
Trig OFF(Free run)
No Exposure Control
Trigger
OFF
OFF
Trig OFF(Free run)
Exposure Control
Is possible
Trigger
OFF
ON
Trig On
EPS
Trig OFF(Free run)
No Exposure Control
Trig On
Trigger
OFF
PWC
OFF or
ON
OFF
ON
 FrameStart trigger: Set whether the start of the frame is to be controlled
externally or not.
TriggerMode On:
While AcquisitionActive is effective and ExposureMode is
set at Timed or TriggerWidth, start exposure using the
signal selected by FrameStart trigger.
TriggerMode Off:
While AcquisitionActive is effective, self-running operation
takes place.
9.2.1.3 Stream control
The signal readout from the CCD can be stored in the frame memory and the stream
control determines the timing of the readout as the stream. This can be compared
to delayed readout in the previous model.
◆
JAI Acquisition Transfer Start:
Trigger Mode ON :
Set the start of the stream externally.
When AcquisitionActive is active, the
stream is output by JAI Acquisition
Transfer Start.
If AcquisitionActive is active status, the
stream can be output.
Trigger Mode OFF:
9.2.2 Triggersoftware
This is one of the trigger sources and is the software trigger command.
This has one command signal to each of the 6 items of TriggerSelector.
To use this function, TriggerSource must be set at TriggerSoftware.
9.2.3 Triggersource
The following signals can be selected as the trigger signal source.