Download Tecplot 360 User`s Manual - SCC

Transcript
FLOW-3D Loader
For more information on working with transient data, refer to Section 7 - 2 “Time Aware”.
• Calculate Derived Variables - Use the Calculate Derived Variables region of the dialog to opt
to include the Complement of F. The complement of F is calculated as:
Complement of F = {1 - f} • {vf}
where f is the fluid fraction and vf is the volume fraction.
The Fluid Surface, where Fluid Surface = {vf}*{f}, is always calculated and added to the dataset.
• Include Boundary Cells On - Use the boundary cell region of the dialog to specify whether to
load boundary cells on the I, J, or K extrema. An additional layer of boundary cells will be
loaded on the given side of each block for each extremum selected.
• Load on Demand - Toggle-on “Cache unloaded data in temporary directory” to enable Tecplot
360 to create a temporary directory to cache the data. The data in the temporary directory is
formatted such that it may be quickly read back into Tecplot 360 as needed.
4 - 7.2
FLOW-3D Macro Commands
The $!READDATASET macro command extended for the FLOW-3D loader with the following options:
Keyword
Values
Default
StandardSyntax
1.0
None
FILENAME_File
Path to flow-3d results
file
none
“Restart”
Notes
Specifies the path to the file to load.
DataGroup
"Selected" or "Restart
IncludeParticleData
"Yes" or "No
“No”
"
DeriveCompOfF
"Yes" or "No
“No”
"
Append
"Yes" or "No
“No”
"
AutoAssignStrandIDs
"Yes" or "No
“Yes”
ZoneList
Set of zone numbers to
load from the file.
All
FLOW-3D refers to these as "blocks." Really, they are a set
of zones that will belong to the same StrandID.
VarNameList
Set of variable names to
load from the file
All
X, Y, X, and "Fluid Surface" are always loaded
DataView
“Internal” or
“External”
IncludeBoundaryCells
“YES/NO”
“YES/NO”
“YES/NO”
“YES/NO”
“YES/NO”
“YES/NO”
"Specifies which data group to load from the file.
"
External
Specify whether to view the data as an internal or external
flow solution.
“Yes” for
all entries
Specify 6 boolean values for including boundary cells.
The values are use the following order for the boundary
cells:
IMIN, IMAX, JMIN, JMAX, KMIN, KMAX
Refer to Scripting Guide for additional information regarding Tecplot 360’s macro language.
4 - 7.3
FLOW-3D Auxiliary Data
The following auxiliary data is added to the dataset by the loader:
Auxiliary name
Value
Common.UVar
Number of variable "U"
Common.VVar
Number of variable "V"
Common.WVar
Number of variable "W"
Common.VectorVarsAreVelocity
TRUE
Common.PressureVar
Number of variable "P"
91