BLIND FUNCTIONS
CFM supports numerous blind functions, all of which are programmable. Blind functions are
those which operate stops at the organ without moving them at the console. Blind functions
include:-
♦ Ventils
♦ Tuttis & Sforzandi
The CFM system has blind function pistons, these pistons may be programmed to operate as
desired. A full explanation of the setting procedure is given below.
If your console is equipped with a SCOPE piston or switch, you will be able to change which type
of blind function is associated with each switch or piston.
If your console is not equipped with a SCOPE control you will not be able to change the function
type of a blind function. However, you will be able to change the stops which are turned on or
off by the blind function.
For Example: you will not be able to change an inclusive tutti to an exclusive tutti, although you
will be able to change which stops the inclusive tutti brings on. Your organ builder will be able
to set this for you.
CRESCENDO
CFM-300 supports 3 programmable
crescendos and one pre-programmed
crescendo.
Crescendo Standard is set by the organ
builder and is the same for all banks and
memory levels. Crescendo A, B and C are
settable by the organist and can be set
differently for each of the banks available to
you.
The crescendo is an inclusive function
which adds stops to those already drawn at
the console.
Each crescendo has 60 stages. The current
stage of the crescendo is displayed in green
on the right of the master control panel
CFM-300 Operation Guide
Figure 3 The Crescendo Control panel.
Revision Dated: 15 December 2009
Page 19