Download Start-Up 08/2003 Edition - Service, Support

Transcript
Installing the Control System
Cable lengths
The maximum cable length depends on the specifications of the encoder
power supply and on the transmission frequency.
To provide fault-free operation, make sure that the following values are not
exceeded when using preassembled interconnecting cables from SIEMENS:
Table 2–6 Maximum cable lengths depending on the encoder power supply
Supply Voltage
Tolerance
Current Consumption
5 V DC
5 V DC
4.75 V...5.25 V
4.75 V...5.25 V
< 300 mA
< 220 mA
Max. Cable
Length
25 m
35 m
Table 2–7 Maximum cable lengths depending on the transmission frequency
Encoder Type
incremental
2.3.3
Frequency
1 MHz
500 kHz
Max. Cable Length
10 m
35 m
Configuration of the RS232 interface connection (X2)
Pin assignment of connector on the CNC side
RS232 interface
Connector designation: X2
RS232
Connector type:
9-pin sub-D plug connector
Table 2–8 Pin assignment of connector X2
Pin
1
2
3
4
5
Name
RxD
TxD
DTR
M
Type
I
O
O
VO
Pin
Name
6
DSR
7
RTS
8
CTS
9
Type
I
O
I
6
9
1
5
Signal description:
RxD
Receive Data
TxD
Transmit Data
RTS
CTS
Request to send
Clear to send
DTR
Data Terminal Ready
DSR
Data Set Ready
M
Ground
Signal level
RS232
SINUMERIK 802S base line
Start-Up
2-11