Download 3 - ElectricalManuals.net
Transcript
3 HUMAN INTERFACES. SETTINGS & ACTUAL VALUES 3.1 ENERVISTA 650 SETUP SOFTWARE INTERFACE 3.1.9 ACTUAL VALUES MENU OVERVIEW The menu bar in the main screen of EnerVista 650 Setup software shows the ACTUAL menu option. This option concentrates and displays all the status of protection, control elements, metering, counters information, oscillography, events, fault locator, etc. This section shows only the structure of menus in EnerVista 650 Setup. Table 3–15: GENERAL OVERVIEW OF ACTUAL VALUES MAIN MENU: ACTUAL Front Panel The relay front LEDs status is shown on this menu. Status Protection and control status signals for all available protection functions in device. Metering All metering values available in device. Primary and secondary values, frequency and phasor diagram provided. Inputs/Outputs All input and output status provided. For contact inputs and contact outputs as well as virtual input and virtual output signals. Records Only enabled in on line mode, retrieval of all the available records in device. Snapshot events, control events, oscillography and fault reports. 3 3.1.9.1 FRONT PANEL The front panel menu shows only the LEDs submenu where all the front LEDs can be monitored. 3.1.9.2 STATUS The following menu includes all the available protection status in the device. Table 3–16: GENERAL OVERVIEW OF STATUS MENU: STATUS GEK-113000T Operation bits Up to 24 elements. OPERATION BIT XX is (0) when the configured time out for the operation XX expires or when success conditions are met. And it is (1) if operation XX is executed and interlocks are fulfilled. Breaker Breaker status (open, closed or undefined). The rest of the status signals corresponding to the switchgear XX configured as breaker are in the “Status>Switchgear Status>Switchgear XX” menu. Protection Status of all the protection units in the device. Control Elements Status of all the control units available in the device. Protection Summary This screen shows a complete list of all protection and control elements in the relay, showing their status (enabled or not). Snapshots events summary Summary of the snapshot events status (enabled or disabled) for protection, control, inputs and outputs boards and switchgear. ModBus User Map Up to 256 elements. Value in SIGNED INT 16 BIT format of the reading for the selected address configured in “Setpoint>Product Setup>ModBus User Map” Switchgear Status Up to 16 blocks of switchgear status signals for the 16 configurable devices. Status signals such as inputs for A and B contacts, status for A and B, open and close status, error 00 and error 11, open init and close init, fail to open and fail to close signals. Calibration Internal states for calibration. Factory calibration and calibration error signals. Flex Curves Flex curve status for A, B, C and D user curves. (0) if it is not configured, (1) if it is configured. To configure a flex curve go to “Setpoint>System Setup>Flex Curves” menu. System Info This screen can monitor the system parameters and the internal status of the Relay operative system. Not enabled by default, password required Records Status Information related to the different records stored in the Relay, such as: Fault reports, control events, oscillography, data logger, demand, energy, and breaker maintenance. SNTP-IRIG-B Information related to synchronization via IRIG_B or SNTP F650 Digital Bay Controller 3-23