Download S300 Safety laser scanner
Transcript
Configurable functions Chapter 4 Operating instructions S300 Static 1-of-n sampling With 1-of-n sampling you use the single connections of the control input pairs. In this way the S300 Advanced provides four and the S300 Professional/Expert six input connections. Notes Using external inputs, maximally ten input connections can be used (e.g. those of a Flexi Soft safety controller, see section 4.5 “Inputs” on page 37). All connections must be connected! One connection must be 1! Only one connection is ever allowed to be 1! Tab. 19: Truth table for 16of6n sampling A1 A2 B1 B2 C1 C2 D1 D2 E1 E2 E.g. case 1 0 0 0 0 0 0 0 0 0 1 0 1 0 0 0 0 0 0 0 0 2 0 0 1 0 0 0 0 0 0 0 3 0 0 0 1 0 0 0 0 0 0 4 0 0 0 0 1 0 0 0 0 0 5 0 0 0 0 0 1 0 0 0 0 6 0 0 0 0 0 0 1 0 0 0 7 0 0 0 0 0 0 0 1 0 0 8 0 0 0 0 0 0 0 0 1 0 9 0 0 0 0 0 0 0 0 0 1 10 1 1 0 0 0 0 0 0 0 0 Error 0 0 0 1 1 0 0 0 0 0 Error 0 0 0 0 0 0 0 0 0 0 Error and all other combinations 50 © SICK AG • Industrial Safety Systems • Germany • All rights reserved Error 8010948/XK33/2013-10-07 Subject to change without notice