Chapter 4. Configuration
does not receive a command in the number of seconds
set in S40, the DSU goes into data mode.
Off>On Dial #1
Dial stored #1. TR goes off to on (SW56 only).
Off>On Dial #2
Dial stored #2. TR goes off to on (SW56 only).
Auto Answer
Specify how incoming calls are to be answered. If
ENABLED, incoming calls are automatically answered by
the DSU III AR. If DISABLED, an incoming call can be
answered manually by an AT or V.25 command from the
DTE, or by raising TR from the DTE. The factory default
setting is ENABLED.
SR Control
The SR OPTIONS menu is used to select the operating
mode for the data set ready (SR) lead. The factory
default setting is OFF TEST ONLY.
Forced On
The SR control lead remains on regardless of the state of
the network.
Off OOS Only
The SR control lead is on except when the DSU III AR
Rackmount receives an out-of-service condition from the
network.
Off LOCD Only
The SR control lead is off five seconds after disconnect
(SW56 only).
Off Test Only
The SR lead is on except when the DSU III AR
Rackmount is executing a test.
24
DSU III AR Rackmount User Manual
61200.034L1-1