3.1.5 Using Pulse Data
CAUTION
• The contents of the pulse data vary according to the ROM version of the main body.
• Pulse data may not be obtained via the optical link according to the ROM version of the main body.
(1) 6-unit system (not applicable to broadcasting)
Table 3-1-33
Address
%IW¨. 9
%IW¨. 10
%IW¨. 11
%IW¨. 12
¨
No
10
11
12
13
Name
Pulse train position reference (PG (PR))
Position detection (built-in or PG (PD))
Position detection (Z phase input) (PG (PD))
S05: Position reference
FS/BS
1/1
1/1
1/1
1/1
Type
INT
INT
INT
INT
Direction
VG7S→UPAC
VG7S→UPAC
VG7S→UPAC
VG7S→UPAC
Remarks
: 1 to 6 (INV1 to INV6)
3.1.5.1 Acquiring pulses
Ⅶ
Command pulse
selection
o12
Internal speed
command
Pulse train position
reference
=1
Oscillating
circuit
OPC-VG7-PG(PR)
Receiving
circuit
=0
Feedback
pulse selection
OPC-VG7-PMPG
PMPG
priority
Standard built-in
OPC-VG7-PG(PD)
o13
Pulse train input
type selection
o05
=0
=1
Receiving
circuit
UPAC position detection,
built-in or PG (PD)
UPAC position detection
(Z phase input) PG (PD)
Fig. 3-1-36
Place a check mark at the pulse train position
reference (PG (PR)) check box in the I/O
Group setting screen of output definition at
UPAC System_Definition - I/O group setting
of the D300win screen. Next, download the
system definition and reset.
Fig. 3-1-37
3-24