- Appendix C: Peripherals
The need for peripherals in this project is abundantly apparent. We used many different
measurement and control systems to be able to achieve our goals. These peripherals were:
- Data Acquisition Unit ( iUSBDAQ-U120816) from Hytek Automation
- Ocean Optics Spectrometer (HR2000)
- Oriel Instruments Encoder Mike Controller (18011)
- Microscope (heavily customized Olympus 230997)
- Logitech USB camera
- Beam splitter (Newport parts manufactured in-house)
C1: Data Acquisition Unit
Figure C1.1 Hytek Data Acquisition Unit
The data acquisition unit was brought on board due to a need for triggering a circuit
based on amount of light collected by the photodiode. This made it so that instead of creating a
new logic circuit every time we changed the gain stage of the amplifier, the logic could be
controlled with a Labview VI. This also took out the guess work for a logic chip. In the
specification sheet for a 7400 series logic component, there was a large range of voltages that
were specified to be undefined logic. The DAQ took a lot of the uncertainty out of the logic.
The DAQ is accurate to within 3 mV DC on its 8 available channels of analog inputs. It also can
25