Download 3 - AutomationDirect

Transcript
Chapter 3: I/O Wiring and Specifications
Wiring & Dimensions
89 (3.5)
9.2 (0.36)
54.3(2.14)
Output Points
0 1 2 3 4 5 6 7 8 9 10 11 12 13 1415
Commons (not isolated)
COM 0
V0
Module Supply
24 VDC
COM 1
V1
COM 2
V2
COM 3
25.7(1.01)
Load
4K ohm
minimum
V3
Note: V 2 and V 3 internally
Note: V 0 and V 1
internally connected connected to Commons
8.1 (0.32)
NOTES:
1. Shields should be connected to the 0 V terminal of the module or the 0 V of
the power supply.
2. Unused voltage outputs should remain open (no connections) for minimum
power consumption.
Unipolar Ranges
0V – 5V
5V
10V
0V
0V
0
4095
0
mm (in.)
83.3 (3.28)
Bipolar Ranges
–5V to +5V
0V – 10V
4095
–10V to +10V
+5V
+10V
0V
0V
–5V
0 (+2047) +4095
–10V
80 (3.15)
8.1 (0.32)
Side View
0 (+2047) +4095
Equivalent Output Circuit
Terminator Installation and I/O Manual, 3rd Edition
1
2
3
4
5
6
7
8
9
10
11
12
13
14
A
B
C
D
3–87