Download (CONCISE VERSION) USER MANUAL pickering
Transcript
Appendix A Self-Test Failure Table The self-test is invoked using the *TST? query. It will test most of the Intelligent GPIB Interface card together with internal backplane bus. But it will NOT test each switching module! Bit Value Error Description Suggested Action 0 1 Micro board EPROM fail. 1 2 Micro board RAM fail. 2 4 Micro board PIA fail. 3 8 Micro board GPIA/ACIA fail. 4 16 Micro board µprocessor fail. 5 32 Not used. 6 64 Not used. 7 128 Micro board system fail. Serious Internal Error - If cause is unknown Contact Pickering. 8 256 Interal Bus Line fail. Remove all modules then power up. If *TST? still shows problem then fault lies with backplane or micro board 3447 chips. If OK repeat procedure but adding a module each time until the faulty one appears. 9 512 One or more modules suspect. Use VIEW? to identify the offender. 10 1024 No modules present. System 10/20 will not function properly without at least one module present. 11 2048 Module Self Test Use DI AGNOSTIC? to investigate problem. 12 4096 Not used. 13 8192 Not used. 14 16384 Not used. 15 32768 Not used. pickering 10-921 (Concise Version) IEEE-488.2/RS-232 Interface Module 31