Download Instruction Manual - Speco Technologies
Transcript
Event In – Alarm In This page allows you to configure the input supported by the camera. The Port can be given as Normally Open or Normally Close state, and their Normal state can be configured. An input will be inactive as long as its Normal state equals its Current state. The 2 options for Normal state are NO (Normally Open) and NC (Normally Close). The input is activated when the Current state changes so that it no longer equals the Normal state. • Alarm In Port 1 Setting Click the Enable alarm in port1 checkbox to enable the Alarm In port 1. * Type: The default setting is NO. NO: Normally Open As an example, if the Normal state for a pushbutton connected to an input is Open circuit, this means that as long as the button is not pushed (and the Current state remains as Open circuit), the state will be inactive. NC: Normally Close When the button is pushed, the circuit is grounded, the input's state changes to Grounded circuit and the input will no longer be in its normal state - it will have become active. An input on the camera has an Open circuit when disconnected or when there is a voltage. * - Dwell time: The default setting is 60 seconds. Dwell time means how long time the alarm input signal hold on as an input signaling source. Click the Save button to save the settings, or click the Reset button to clear all of the information you entered without saving it. 30