Download File

Transcript
S
T2
C
T1
R
Flash
Flash
HIGH
PRESSURE
SWITCH
L2
BLACK
BLACK
BLACK
TO 460-3-60
POWER SUPPLY
GND
CONTACTOR
L3
L1
T2
CCH
T1
T3
YE
CRANKCASE HEATER
(IF EQUIPPED)
On
Flash
On
On
YELLOW
G
C
L W1
R
BLACK
Y2
E
WHITE
YE
YE
O Y1 W2
RED
WHITE
BLACK
GREEN
YELLOW
BROWN
BLUE
YELLOW
BLACK
GRAY
AUTO-TRANSFORMER
230V
COM
YELLOW
BLUE
INDUCER
LIMIT
FLAME
ROLL-OUT
LIMIT
460V
BLUE
GREEN
FUSE
LOW
PRESSURE
SWITCH
BLUE
HIGH
TEMP
LIMIT
BLUE
R
TEST PORT
DEHUM
WHITE
INDUCER
HALL
SWITCH
C Y1
BLOWER CONTROL
BOARD
W1
EXPANSION
PORT
WHITE
BLACK
1
1
2
3
P8
RED
9
8
7
6
5
4
3
2
1
HPS
DISCHARGE
AIR SENSOR
9
8
7
6
5
4
3
2
1
ORANGE
BLUE
YELLOW
BLACK
GREY
GREEN
RED
RED
RED
9
8
7
6
5
4
3
2
1
9
8
7
6
5
4
3
2
1
VIOLET
VIOLET
GREEN
WHITE
ORANGE
YELLOW
BROWN
BLACK
GREEN
ECONOMIZER JUMPER
HARNESS ASSY 8-WIRE
RED
RED
FLAME
SENSOR
24V INPUT
24V OUTPUT
GREEN
WHITE
RED
TWIN
BLOWER
HARNESS
INDOOR
BLOWER
MOTOR
9
6
3
5
2
1
4
ECONOMIZER
PLUG
YELLOW
11 12
8
7
10
G
1
2
3
4
C R
BLACK
5
BLWR OFF
DELAY
GAS
CONTROL
YELLOW
BROWN
WHITE
RED
BLACK
RED
BROWN
BROWN
BLACK
WHITE
Flash
COM
24V
3
2
1
IGNITOR
INDUCER
MOTOR
01/29/14
7113840
3
2
1
TRANSFORMER
230
208
RED
COM
HIGH
LOW
2 STAGE
GAS
VALVE
Yellow LED
Continuous Flash
On
Off
Green LED
Red LED
Off
Off
Flash
Flash
Alternating Flash
On
On
On
Flash
Flash
On
Flash
Off
On
Off
RED
BLACK
GREEN
BLUE
ORANGE
WHITE
Diagnostic Description
Control Fault (No Power)
L1/ Neutral Polarity Fault
1 Hour Lockout
Normal Operation
Pressure Switch Stuck Closed with Inducer Off
Pressure Switch Stuck Open with Inducer On
Open Limit Switch Fault
Motor Fault
Pressure Switch Open Fault
(Blocked Vent or Condensate)
Diagnostic Description
Low Flame Sensor Signal
Flame Present
1. Couper le courant avant de faire letretien.
2. Employez uniquement des conducteurs en cuivre.
EAC
LEGEND:
FIELD WIRING
LOW VOLTAGE
HIGH VOLTAGE
COMPRESSOR
T3
YELLOW
OUTDOOR
FAN MOTOR
Off
Off
YELLOW
YE
Red
LED
BLACK
Green
LED
WHITE
BLOWER MOTOR
RED GREEN
Blower Control
Diagnostic
Description
Control Fault (No
Power)
Normal Operation
Motor Fault
Communications
Fault
BLACK
P4
BLACK
STATUS
3. For replacement wires use conductors suitable for 105 deg.C.
4. For ampacities and overcurrent protection, see unit rating plate.
Y1
HEAT COOL
460 Volt / 3 Phase / 60 Hz
W2
W1
3-5 Ton Package 2 Stage Gas/Single Stage Air Conditioner
BLACK
BLACK
2 3
1
NOTES:
1. Disconnect all power before servicing.
2. For supply connections use copper conductors only.
ORANGE
BLACK
BLUE
BLACK
Y/Y2
XMFR
2
WIRING DIAGRAM
HUM
LINE
LINE
1
LINE- N
2
LINE- N
1
W
RX
TX
COM
C
R
XMFR-N
Figure 15. Three Phase, 3-5 Ton, 460V
39