Download File
Transcript
S T2 C T1 R Flash Flash HIGH PRESSURE SWITCH L2 BLACK BLACK BLACK TO 460-3-60 POWER SUPPLY GND CONTACTOR L3 L1 T2 CCH T1 T3 YE CRANKCASE HEATER (IF EQUIPPED) On Flash On On YELLOW G C L W1 R BLACK Y2 E WHITE YE YE O Y1 W2 RED WHITE BLACK GREEN YELLOW BROWN BLUE YELLOW BLACK GRAY AUTO-TRANSFORMER 230V COM YELLOW BLUE INDUCER LIMIT FLAME ROLL-OUT LIMIT 460V BLUE GREEN FUSE LOW PRESSURE SWITCH BLUE HIGH TEMP LIMIT BLUE R TEST PORT DEHUM WHITE INDUCER HALL SWITCH C Y1 BLOWER CONTROL BOARD W1 EXPANSION PORT WHITE BLACK 1 1 2 3 P8 RED 9 8 7 6 5 4 3 2 1 HPS DISCHARGE AIR SENSOR 9 8 7 6 5 4 3 2 1 ORANGE BLUE YELLOW BLACK GREY GREEN RED RED RED 9 8 7 6 5 4 3 2 1 9 8 7 6 5 4 3 2 1 VIOLET VIOLET GREEN WHITE ORANGE YELLOW BROWN BLACK GREEN ECONOMIZER JUMPER HARNESS ASSY 8-WIRE RED RED FLAME SENSOR 24V INPUT 24V OUTPUT GREEN WHITE RED TWIN BLOWER HARNESS INDOOR BLOWER MOTOR 9 6 3 5 2 1 4 ECONOMIZER PLUG YELLOW 11 12 8 7 10 G 1 2 3 4 C R BLACK 5 BLWR OFF DELAY GAS CONTROL YELLOW BROWN WHITE RED BLACK RED BROWN BROWN BLACK WHITE Flash COM 24V 3 2 1 IGNITOR INDUCER MOTOR 01/29/14 7113840 3 2 1 TRANSFORMER 230 208 RED COM HIGH LOW 2 STAGE GAS VALVE Yellow LED Continuous Flash On Off Green LED Red LED Off Off Flash Flash Alternating Flash On On On Flash Flash On Flash Off On Off RED BLACK GREEN BLUE ORANGE WHITE Diagnostic Description Control Fault (No Power) L1/ Neutral Polarity Fault 1 Hour Lockout Normal Operation Pressure Switch Stuck Closed with Inducer Off Pressure Switch Stuck Open with Inducer On Open Limit Switch Fault Motor Fault Pressure Switch Open Fault (Blocked Vent or Condensate) Diagnostic Description Low Flame Sensor Signal Flame Present 1. Couper le courant avant de faire letretien. 2. Employez uniquement des conducteurs en cuivre. EAC LEGEND: FIELD WIRING LOW VOLTAGE HIGH VOLTAGE COMPRESSOR T3 YELLOW OUTDOOR FAN MOTOR Off Off YELLOW YE Red LED BLACK Green LED WHITE BLOWER MOTOR RED GREEN Blower Control Diagnostic Description Control Fault (No Power) Normal Operation Motor Fault Communications Fault BLACK P4 BLACK STATUS 3. For replacement wires use conductors suitable for 105 deg.C. 4. For ampacities and overcurrent protection, see unit rating plate. Y1 HEAT COOL 460 Volt / 3 Phase / 60 Hz W2 W1 3-5 Ton Package 2 Stage Gas/Single Stage Air Conditioner BLACK BLACK 2 3 1 NOTES: 1. Disconnect all power before servicing. 2. For supply connections use copper conductors only. ORANGE BLACK BLUE BLACK Y/Y2 XMFR 2 WIRING DIAGRAM HUM LINE LINE 1 LINE- N 2 LINE- N 1 W RX TX COM C R XMFR-N Figure 15. Three Phase, 3-5 Ton, 460V 39