Download SX77 Series Advanced Process Controller
Transcript
SX77 4-07-2008 8:59 Pagina 59 7 - Programmed Setpoint 7 PROGRAMMED SETPOINT INTRODUCTION When the Setpoint programmer option is present, up to four programs are available. MAIN CHARACTERISTICS • 4 program, 16 segments max/program • start, stop, hold etc, commands from the keypad • time base in seconds, minutes or hours • continuous or up to 1…9999 time cycling of the program • two digital outputs (OP3 and OP4) related to the program. • setting of the maximum allowed deviation from the Setpoint 7.1 PROGRAM STRUCTURE The program consists of a sequence of segments. For each segment, it is specified: • the Setpoint to reach #s.p. always • the duration present of the segment #t.i. The program consists of: • 1 initial segment named O • 1 end segment named f • 1…14 normal segments Initial segment - 0 Its main purpose is to define the value the process variable has to maintain before starting the program. Ramp #s.p.== #ti.== Dwell • the state of the OP3 output #s.p.== #ti.== End segment - F Its main purpose is to define the value the process variable has to maintain at the end of the program and until further changes of Setpoint. Normal segments - === These segments build up the profile program. There are 3 types of segments: #ti.== #s.p.== Step #s.p.== #ti.== = 0 s.p. ti. = Target Setpoint =Duration =Previous segment =Current segmente =Next segment 59