Transcript
OLICORP IRS SERIES 07/02/2013 Cabling and lamps strategy : It is possible to use the NS-IRS cabinet with several types of lamps and with different cabling topologies. - The NS-IRS automatically limits the Voltage sent to the lamp according to the type of lamp. It is thus possible to use 400 VAC lamps on 480 VAC supply. - The total current regulated by the power cabinet cannot exceed 65A for NS-IRS and 75 A for the IRS12. The total current / channel cannot exceed 7.5 A / channel for both products. The Overload current is set to 200 A. - NS-IRS Absolute maximum ratings : The NS-IRS is accepting input voltage between 185 VAC and 530 VAC, with frequencies ranging between 47 and 63 Hz. Power supply Voltage (VAC) +/-10% Lamp Nominal Voltage (Vrms) 208 230 400 415 440 480 230 ------------- 1700 1000 950 900 820 360 ------------- ------------- 2400 2300 2200 2000 400 ------------------------3000 2900 2700 2500 Green : Maximal power (W) for lamps for a given Power supply voltage and lamp nominal voltage. The minimal setting per channel is 10% of the nominal power of the lamp in power regulation mode. This limit is set to avoid current bursts with tungsten lamps as the Resistance of the lamp may slightly decrease when running at low power. - 15 -