Download FADEC system-Autostart version PRELIMINARY
Transcript
Description of the FADEC. The FADEC (Full Authority Digital Engine Control) is a total system for the control of a model gas turbine engine. Its main function is to control and regulate the fuel pump, providing to the turbine engine the necessary amount of fuel for safe and controlled operation. The FADEC measures the exhaust gas temperature, the relative position of the throttle stick and the rotor speed. It monitors all of the controls necessary to guarantee that the engine stays between the user defined parameters of operation, also providing failsafe shutdown of the engine when it has detected any important anomaly. In order to make this assessment, the FADEC has a rpm sensor, a thermocouple input, a throttle servo input, power connections for the fuel pump, starter, glow plug, fuel and gas valves and the battery and a digital (RS232) serial port to program and read the data in real-time to a PC. The measurements made by the FADEC are: ?? ?? ?? ?? ?? ?? Temperature of the exhaust gas Pump battery voltage Width of the throttle pulses from the radio transmitter Engine rotor RPM Engine run time. External analog signal. All of these FADEC measurements can be read into and displayed on the Handheld Data terminal (HDT) that is connected to the FADEC by a RJ-45 connector, or into a personal computer trough a RS232 adapter. The FADEC is totally programmable by the user to adapt the margins of operation of each individual turbine engine. The configuration/setup parameters are stored in the FADEC by the terminal of hand or the PC. Features: ?? ?? ?? ?? ?? ?? ?? ?? ?? ?? ?? ?? ?? ?? ?? ?? ?? ?? RPM input: Hall effect or Infrared. Factory set. RPM range up to 250.000 RPM Temperature range up to 1000ºC using a "K" type thermocouple PWM control of 1024 levels for pump, glow plug and starter motor. Battery Voltage from 4,8 to 12V Adjustable power for the starter motor Build-in electronic brake for the starter motor to help the clutch to disengage. Blown glow-plug detector Adjustable glow-plug power Glow-plug temperature independent of the battery voltage Adjustable gas off temperature Adjustable rpm starter switch on and off. Engine running timers 2 status LEDs on the unit plus 2 more remote on option RS232 interface to interface to a PC. Software upgradable trough the Data Terminal connection. Black box function. Record the engine measures each 0.5sec up to 12 minutes. User programmable acceleration and deceleration ramps. (8 points each curve in running mode and 3 point in start mode) Adjusting the parameters: On this software version there are 2 sets of parameters that can be changed. The "operator" parameters are adjustable trough the Data Terminal using normal menus. The "manufacturer" parameters are accessible by a special procedure and in some software versions, are only accesible by the manufacturers. The PC software can program all of the parameters if the user have the rights to do it. The operator parameters are: ?? ?? ?? ?? ?? ?? ?? ?? ?? ?? ?? ?? Radio throws adjust. Maximum rpm Idle RPM Stop RPM Minimum temperature Maximum temperature Acceleration time Deceleration time Stability time Pump start point Pump start ramp Glow plug power From these parameters, the readings of the engine and the position of the throttle control, the FADEC adjusts the power to the fuel pump in the following way: First, the FADEC verifies that the control pulse of the transmitter is correct, that is to say, is between the limits set by the user. If the pulse is not correct, or the pulses are not received during 0.5 seconds, the system assumes that there is a trouble with the radio link and shuts down the engine (fail safe). During this time of delay, the system assumes that the throttle is at idle and decelerates the engine to this power. Once verified that the pulse is correct, the relative position of the throttle stick determined by the limits programmed by the user is calculated. This calculation gives a value between 0% and 100% that can be read on the HDT or a PC. This value is Fadec Autostart User’s Manual. V0.9 24/12/01 2/12