21
Press the
menu key to accept the change
or
Select Return at the top of the menu and press Enter.
Viper will not make the change of the I/O-allocation until you
accept it.
If the change of the I/O-allocation is possible, Viper will accept
it.
If the change is not possible, Viper will reject, and the I/Oallocation will continue as previously.
Viper rejects the change of the I/O-allocation if:
• you have manually used all DOL 12 inputs for other analog inputs
• you have manually used relays so that there are no free relays for the relay-controlled
shutters
Instead, manually select terminal for all temperature sensors and subsequently for all relay-controlled
shutters.