Download Multi Format IO Module User Manual

Transcript
Serial Commands
Reset
Function
Set Reset
Command
Response
Description
RESET +001;
ASC-MIO1 00;
Reset all settings.
RESET +002;
ASC-MIO1 00;
Reset video wall settings.
Button
Function
Set button
Check button
Command
Response
Description
BUTTON +000;
ASC-MIO1 00;
Set button to repeat rate off.
BUTTON +001;
ASC-MIO1 00;
Set button to repeat rate default.
BUTTON +002;
ASC-MIO1 00;
Set button to repeat rate slow.
Button?;
BUTTON +000;
Button is repeat rate off.
BUTTON +001;
Button is repeat rate default.
BUTTON +002;
Button is repeat rate slow.
Timeout
Function
Command
Variables
Set TimeOut
TIMEOUT XXXX;
xxxx = Timeout number
+000 – +060
Command Example
Response
Description
TIMEOUT +015;
ASC-MIO1 00;
Set timeout to 15 seconds.
Function
Check Timeout
Command
TIMEOUT?;
Multi Format IO Module User Manual
020-000699-01 Rev. 1 (03-2014)
Response
Description
TIMEOUT +001;
Timeout setting is 1 second.
TIMEOUT +015;
Timeout setting is 15 seconds.
31