B. TROUBLE SHOOTING
☞ System operates abnormal.
Cause
Solution
Of that user mistake, memory (SRAM) is damaged, or the system is defective of the
device.
1. Check BAT connection Switch(place template hole of reverse side).
You have to push up the Switch, and system initialize before system installation.
Figure: DIP SWITCH SETTING
Figure: DIP SWITCH LOCATION
2. If the trouble remains after checking the above, contact a designated service center.
☞ Broken or abnormal letters shown on the LCD, when powered on.
Cause
Solution
SRAM backup battery problem or LCD module problem.
1. Initialize the controller
- Connect the cyan wire, pink wire and black wire together.
- Switch the main power on.
- Enter key <1>.
- Check if the LCD shows the message “Initialize END” “turn off Power…”.
- Switch main power OFF.
- Separate 3 wires (pink, cyan and black (GND) ).
- Switch main power ON again.
* Aware that all the setting values will be back to the default value and data
memory will be cleared. (ID data clear/Event data clear/ Time Schedule data
clear/ etc.)
2. Set up the date and time on SETUP MENU F1->SYS INITIALIZE and SETUP MENU
F1->TIME SETTING.
3. If you still have problems, please contact a designated service center.