<Function 065> GS ( k pL pH cn fn n (when fn = 65)
[Format]
ASCII
Hex
Decimal
GS
1D
29
(
28
40
[Range]
(pL + pH × 256) = 3
cn = 48
fn = 65
0 ≤ n ≤ 30
[Default]
n=0
k
6B
107
pL
pL
pL
pH
pH
pH
cn
cn
cn
fn
fn
fn
n
n
n
(pL = 3, pH = 0)
[Description] Sets the number of digits (step size) of the data area for PDF417 symbols.
• When n = 0, specifies automatic processing
• When n ≠ 0, sets the number of digits of the data area to n codewords.
• When the automatic processing (n = 0) is specified, the number of columns per row
is calculated with the number of codewords or the range of printable area.
[Notes]
The following data is not included in the line number.
• Start and stop patterns
• Left and right indicator codewords
[Reference]
Appendix J
<Function 066> GS ( k pL pH cn fn n (when fn = 66)
[Format]
ASCII
Hex
Decimal
GS
1D
29
(
28
40
[Range]
(pL + pH × 256) = 3
cn = 48
fn = 66
n = 0, 3 ≤ n ≤ 90
[Default]
n=0
k
6B
107
pL
pL
pL
pH
pH
pH
cn
cn
cn
fn
fn
fn
n
n
n
(pL = 3, pH = 0)
[Description] Sets the step size of PDF417 symbols
• When n = 0, specifies automatic processing
• When n ≠ 0, sets the height of the symbol steps to n.
• When the automatic processing (n = 0) is specified, the number of columns per row
is calculated with the number of codewords or the range of printable area.