■ Questions about the application.
Q
Is it possible to use with phase modulation type(BRT) resolver?
A
No. This product only support amplitude modulation type(BRX) resolver.
Q
Is it possible to use multiple AU6802N1 which connect same one resolver?
A
It is basically usable if same exciting signal input to each IC’s R1E/R2E terminals.
However in case of error at external exciting amplifier and RSO output abnormality of
exciting signal source IC, all R/D system becomes unavailable.
Note that it must be required to put capacitor between RSO and COM regardless RSO
output use or not.
Q
How much cable length between resolver and AU6802N1 can we extend?
It can not to say simple because it depend on the type of cable and wiring, but basically
there are not much problem about cable length itself which is a few meters except for
noise superimposed, etc.
A
Example for extremely long cable length is about 150m extended application exist and
proven. Anyway it may require for phase adjustment or signal level adjustment, etc,
because long cable might cause phase shift or amplitude change due to cable capacity.