room.
Room
temperature
temperature
sensor.
programmer
Activation
of
requires
installation
Programator
of
internal
pokojowy
(Room
temperature thermostat) is set in Parametry użytkownika – Regulator
temperatury
wewnętrznej
(User
parameters
-
Internal
temperature
regulator): Pokojowy (Room).
If internal temperature exceeds set value of the programmer, set temperature
is reduced by the CH temperature decrease value. Additionally CH pump may
operate in three (3) modes: Continuous, cyclic and OFF ( after reaching set
temperature in the room). CH pump operation mode after reaching set
temperature is set in Ustawienia zaawansowane (Advanced settings): Tryb
pracy pompy CO dla reg. wewnętrznego (CH pump operation mode for
internal regulator). For cyclic CH pump operation, operation and idle time are
set with the following parameters: Czas pracy pompy CO dla reg.wew (CH
pump operation time for internal temperature regulator) and Czas postoju
pompy CO dla reg.wew. (CH idle time for internal temperature regulator).
The settings also apply to active thermostat.
Item
Parameter
Description
1
Temperatura dzienna (Day Day temperature maintained in the room. Range [5°C
temperature)
to 35°C]
2
Temperatura nocna (Night
temperature)
Night temperature maintained in the room. Range
[5°C to 35°C]
3
Histereza (Hysteresis)
The parameter determines value by which the internal
temperature is reduced, to start the room heating
procedure. Range [0.1°C to 2.0°C]
4
Tablica dobowa (Daily
schedule)
Daily schedule to set time intervals for day and night
temperature. Upper dash – day temperature, bottom
dash – night temperature.
39/67