Download Reference Manual

Transcript
Data Source Configuration
Configuring Data Sources
The Server Type radio button indicates the type of computer on which the DBE is located. Click
on:
MPE/iX if it is an HP3000
HP-UX if it is an HP9000
Setup for MPE/iX
Figure 9
The SessionID, User Name, Acct Name, Group Name, User Password, Acct Password and
Group Password entries correspond to those used if you were manually connecting to the
HP3000 or HP9000. If you don't know this information, contact your System Manager.
If you want the client application to prompt for the passwords at run-time, enter a “?” in the
password field. If you put a question mark in any password field, you will get a dialogue box
and be prompted to enter the password every time you run your application and request a
connection. For an attached table in MS-Access, ODBCLink/SE will not store the password
anywhere within the application, so you will have to enter the password the first time you open
the table. However, many applications, including Access, connect more than once to the same
data-source, and if you have already entered the passwords and created a new connection, you
will not normally have to enter it again for additional connections to the same data-source.
As you might expect, "mandatory" means you must enter a value. However, "optional" doesn't
necessarily mean you don't have to enter a value; it means there may not be a value required.
For example, on the MPE/iX logon, "Session ID" is any 8 characters you choose, starting with
an alphabetic character with no embedded blanks. You may choose not to enter a "Session ID".
On the other hand, "Group Name" will default you to your "home group" so may be left blank;
if your "User Name" does not have a "home group" this field is required or the connection will
fail.