HE2020.com.au Unit 6/6 Tennyson Street, Clyde, NSW, 2142 Tel.02 9637 3737 Fax.02 9637 3434 E.info@he2020.com.au - check that the condensated steam outlet pipe can freely drain by drop. 12 - Insufficient aspiration and steam condensation A - Check whether foreign bodies obstruct the upper air exhaust hole . B - Check that the filter of the condenser battery is not clogged by fat residuals. In such an event, wash it with boiling water and detersive. Rinse thoroughly. C - Check that overload cutout is not triggered. If so, restore it. This drawback is dispalyed by lamp M(LS3) being ON . D - Check that fuses and remote switch coil MT16 are not broken. E - Check that motor M08 is not blocked nor burnt and rotates in the right direction F - Check that the cold water feed cock is open and water is present at a pressure of at least 2 bars. G - Check that cold water inlet filter D is not clogged to such an extent as to limit the flow rate. The manufacturer declines any responsibility for any misprints contained in this booklet. The Manufacturer also reserves the right to make any modifications to its products that don't affect the basic characteristics thereof. 47