Download Preface

Transcript
Chapter 7 Setting of Servodrive General Function Codes
IS500 Servodrive User Manual
For example:
If Vcc=+24 V, then, R1=2.4 kΩ;
If Vcc=+12 V, then, R1=1.5 kΩ;
If Vcc=+5 V, then, R1=200 Ω.
Wiring open collector through PL1/PL2/PL3 for pull-up helps to utilize the 24V power supply
in the servodrive.
Servodrive
24V
CN1
3 2.4kΩ
13
18
150Ω
Host controller
/PULS
/SIGN
/CLR
COM
15
14
50
150Ω
Terminals 3, 13 and 18 indicate PL1, PL2 and PL3 respectively.
【Note】
■
7
8
11 150Ω
12
Setting the pulse reference input form
There are four pulse reference input forms, set in H05-15.
Function
Code
H05
Name
Reference Pulse Form
Setting
Range
0: Direction + pulse, positive logic (default value)
1: Direction + pulse, negative logic
2: Phase A + Phase B Orthogonal pulses, 4 multiple frequency
3: CW+CCW
Min. Unit
1
Factory
Setting
0
When
Enabled
After Restart
Data Type
Stop Setting
Related
Mode
P
15