Download MCX314As User`s Manual
Transcript
MCX314As – M64 NOVA electronics Inc. Signal Name Pin No. UECB/PMIN 51 Input/Output Signal Description When the Up / Down pulse input mode is selected, this terminal is for DOWN pulses input. Once the input pulse is up (↑), the real position counter is counting down. Drive/Deviation Counter Clear: Drive status output (nDRIVE) and deviation counter clear output (DCC) share the same pin. Drive status display output (nDRIVE) is set to a High level while drive pulses are output. At execution of automatic home search, this signal is set to a High level. XDRIVE/DCC 56 YDRIVE/DCC 76 ZDRIVE/DCC UDRIVE/DCC 104 122 The axis with interpolation drive specified is set to a High level while the Output A interpolation driving is executed. The DRIVE signal is set to a High level until nINPOS becomes active, while the nINPOS signal for the serve motor is enabled by mode selection. A deviation counter clear output (DCC) signal is output for a server motor driver. The signal can be output by setting the mode in automatic home search. See Sections 2.5.2 and 2.5.3. At resetting, the drive status display output is set. General Output 7 / Descend: general purpose output signals XOUT7/DSND After the axis is appointed by WR0 register, nOUT7~4 can output the 1/0 data of 57 YOUT7/DSND 77 ZOUT7/DSND UOUT7/DSND 105 123 Output A D11~8 in WR3 register to Hi / Low. They become Low when the IC is reset. When the drive status output mode is engaged, this signal can be used for reflecting the status of deceleration. While the driving command is executed and during the deceleration, it becomes Hi. XOUT6/ASND 58 YOUT6/ASND 78 ZOUT6/ASND UOUT6/ASND 106 124 XOUT5/CMPM 59 YOUT5/CMPM 79 ZOUT5/CMPM UOUT5/CMPM 107 125 General Output 6 / Ascend: general purpose output signals (the operation is as same as nOUT7) Output A When the drive status output mode is engaged, this signal can be used for reflecting the status of acceleration. While the driving command is executed and during the acceleration, it becomes Hi. General Output 5 / Compare−: general purpose output signals (the operation is as same as nOUT7) Output A When the drive status output mode is engaged, it becomes Hi if the value of logical / real position counter is smaller than that of COMP−; it becomes Low if the value of logical / real position counter is larger than that of COMP−. General Output 4 / Compare+: general purpose output signals XOUT4/CMPP 60 YOUT4/CMPP 80 ZOUT4/CMPP UOUT4/CMPP 108 128 XOUT3~O 61~64 YOUT3~0 81~84 ZOUT3~0 UOUT3~0 110~113 129~132 XINPOS 67 YINPOS 85 Input A Enable / disable and logical levels can be set as commands. When “enable” is ZINPOS UINPOS 95 114 −F− set, and after the driving is finished, this signal is active and standby. n-DVR bit XALARM 68 (the operation is as same as nOUT7) Output A logical / real position counter is larger than that of COMP+; it becomes Low if the value of logical / real position counter is smaller than that of COMP+. General Output 3~0: 4 general output signals for each axis OUT3~0 can output Output A the 1/0 data of D15~0 in WR4 register to Hi / Low. They become Low when the IC is reset. Compared with the setting of nOUT7~4, it is easier cause there is no need to have the appointed axis. In-position: input signal for servo driver in-position of main status register returns to 0. Servo Alarm: input signal for servo driver alarm YALARM 86 Input A ZALARM UALARM 96 115 −F− Enable / disable and logical levels can be set as commands. When it is enable and when this signal is in its active level, the ALARM bit of RR2 register becomes 1. OVER Limit +: signal of + direction over limit XLMTP 69 YLMTP 87 Input A ZLMTP ULMTP 97 116 −F− 70 Input A XLMTM When the drive status output mode is engaged, it becomes Hi if the value of During the + direction drive pulse outputting, decelerating stop or sudden stop will be performed once this signal is active. When the filter function is disabled, the active pulse width must be 2CLK or more. When it is enable, and when this signal is in its active level, the HLMT+ of RR2 register becomes 1. OVER Limit −: signal of − direction over limit – 64 –