Download MCX314As User`s Manual

Transcript
MCX314As – M64
NOVA electronics Inc.
Signal Name
Pin No.
UECB/PMIN
51
Input/Output
Signal Description
When the Up / Down pulse input mode is selected, this terminal is for DOWN
pulses input. Once the input pulse is up (↑), the real position counter is counting
down.
Drive/Deviation Counter Clear: Drive status output (nDRIVE) and deviation
counter clear output (DCC) share the same pin.
Drive status display output (nDRIVE) is set to a High level while drive pulses are
output. At execution of automatic home search, this signal is set to a High level.
XDRIVE/DCC
56
YDRIVE/DCC
76
ZDRIVE/DCC
UDRIVE/DCC
104
122
The axis with interpolation drive specified is set to a High level while the
Output A
interpolation driving is executed. The DRIVE signal is set to a High level until
nINPOS becomes active, while the nINPOS signal for the serve motor is enabled
by mode selection.
A deviation counter clear output (DCC) signal is output for a server motor driver.
The signal can be output by setting the mode in automatic home search. See
Sections 2.5.2 and 2.5.3. At resetting, the drive status display output is set.
General Output 7 / Descend: general purpose output signals
XOUT7/DSND
After the axis is appointed by WR0 register, nOUT7~4 can output the 1/0 data of
57
YOUT7/DSND
77
ZOUT7/DSND
UOUT7/DSND
105
123
Output A
D11~8 in WR3 register to Hi / Low. They become Low when the IC is reset.
When the drive status output mode is engaged, this signal can be used for
reflecting the status of deceleration. While the driving command is executed and
during the deceleration, it becomes Hi.
XOUT6/ASND
58
YOUT6/ASND
78
ZOUT6/ASND
UOUT6/ASND
106
124
XOUT5/CMPM
59
YOUT5/CMPM
79
ZOUT5/CMPM
UOUT5/CMPM
107
125
General Output 6 / Ascend: general purpose output signals
(the operation is as same as nOUT7)
Output A
When the drive status output mode is engaged, this signal can be used for
reflecting the status of acceleration. While the driving command is executed and
during the acceleration, it becomes Hi.
General Output 5 / Compare−: general purpose output signals
(the operation is as same as nOUT7)
Output A
When the drive status output mode is engaged, it becomes Hi if the value of
logical / real position counter is smaller than that of COMP−; it becomes Low if
the value of logical / real position counter is larger than that of COMP−.
General Output 4 / Compare+: general purpose output signals
XOUT4/CMPP
60
YOUT4/CMPP
80
ZOUT4/CMPP
UOUT4/CMPP
108
128
XOUT3~O
61~64
YOUT3~0
81~84
ZOUT3~0
UOUT3~0
110~113
129~132
XINPOS
67
YINPOS
85
Input A
Enable / disable and logical levels can be set as commands. When “enable” is
ZINPOS
UINPOS
95
114
−F−
set, and after the driving is finished, this signal is active and standby. n-DVR bit
XALARM
68
(the operation is as same as nOUT7)
Output A
logical / real position counter is larger than that of COMP+; it becomes Low if the
value of logical / real position counter is smaller than that of COMP+.
General Output 3~0: 4 general output signals for each axis OUT3~0 can output
Output A
the 1/0 data of D15~0 in WR4 register to Hi / Low. They become Low when the IC
is reset. Compared with the setting of nOUT7~4, it is easier cause there is no
need to have the appointed axis.
In-position: input signal for servo driver in-position
of main status register returns to 0.
Servo Alarm: input signal for servo driver alarm
YALARM
86
Input A
ZALARM
UALARM
96
115
−F−
Enable / disable and logical levels can be set as commands. When it is enable
and when this signal is in its active level, the ALARM bit of RR2 register becomes
1.
OVER Limit +: signal of + direction over limit
XLMTP
69
YLMTP
87
Input A
ZLMTP
ULMTP
97
116
−F−
70
Input A
XLMTM
When the drive status output mode is engaged, it becomes Hi if the value of
During the + direction drive pulse outputting, decelerating stop or sudden stop
will be performed once this signal is active. When the filter function is disabled,
the active pulse width must be 2CLK or more. When it is enable, and when this
signal is in its active level, the HLMT+ of RR2 register becomes 1.
OVER Limit −: signal of − direction over limit
– 64 –