Download coolcept coolcept-x
Transcript
GB 9 9.1 9.1.1 Technical data Inverter StecaGrid 1800/1800x/2300/2300x/3010/3010x StecaGrid 1800/x StecaGrid 2300/x StecaGrid 3010/x DC input side (PV generator connection) Number of DC inputs 1 Maximum start voltage 600 V Maximum input voltage 600 V Minimum input voltage for gridfeeding 125 V Startup input voltage 150 V Rated input voltage 230 V 295 V 380 V Minimum input voltage for rated output 160 V 205 V 270 V 160 V … 500 V 205 V … 500 V 270 V … 500 V MPP voltage for rated output Maximum input current 11.5 A Rated input current 8A Maximum input power at maximum active output power 1840 W 2350 W 3070 W Rated input power (cos φ = 1) 1840 W 2350 W 3070 W Recommended maximum PV output 2200 Wp 2900 Wp 3800 Wp Derating / power limiting occurs automatically when: n n n n n n n n input power > max. recommended PV power cooling is inadequate input current too high grid current too high internal or external derating grid frequency too high (according to country setting) limiting signal received via an external interface output power is limited (set at the inverter) AC output side (grid connection) Output voltage 185 V ... 276 V (depending on the country settings) Rated output voltage 230 V Maximum output current 12 A 14 A 14 A Rated output current 8A 10 A 13 A 747.431 | Z08 | 2014-01-31 133