Chapter 5 Example of Motion Command
5.7 Reverse Speed


Example description

Use M410 as the enabling condition for triggering and executing operation at
reverse speed. After M410 is activated, the related parameters will be executed
and issue the command.
Example program

Cyclic task
a. When M410 turns On, it is in initial control status (D20=0) and resets
【Command start】(R512) at the same time.

b. When M410 is On, it enters sub program, N_Speed, to execute multi-axis
reverse operation. Then, M410 will be Off automatically.
Sub program: N_SPEED
a. When D20 = 0, it starts to write parameters. When 【Command code】(W512)
is set to 5, it means the operation is at reverse direction. Write D400 into
【Command selection】(W513) to select reverse speed axis (When Bit 0 is On,
Jan. 2014
5-13