Download Facilities Services Construction Standards June 2012

Transcript
Division 1 – General Requirements
Page 01 00 01 - 12
a.
F.
Provide adequate clear floor space at any operable window so
that a person can approach and open the windows.
07.
Furnishings
a.
Where seating, benches, tables and other furnishings are
provided, provide a minimum of one accessible unit for every five
units or portion thereof.
Plumbing Elements and Facilities
01.
Restrooms and Toilet Rooms
a.
In new construction and major renovation, all restrooms shall be
designed to be fully accessible.
b.
All restrooms shall be designed either without doors or have
automatic door operators. (See Section 08 71 00 Door Hardware.)
In addition to the required restrooms per applicable building code
c.
d.
02.
03.
04.
Revised June 2012
requirements, at least one accessible family or assisted use restroom
shall be provided. If only one restroom is provided, then it shall be
located on the first floor of the building.
All family or assisted use restrooms shall be provided with a
Camden entry system. (See Section 08 71 00 Door Hardware.)
e.
In restrooms that include two or more toilets, provide at least one
wheelchair accessible stall and one ambulatory accessible stall.
f.
In larger public restrooms containing six or more toilets, provide
one wheelchair accessible stall and one ambulatory accessible
stall for each six toilet stalls or portion thereof.
g.
Provide 48 inches minimum clearance between stall doors and
any wall or obstruction. (ADA allows 42” for latch side approach.)
h.
Install automatic flush valves. Exception: Where dual-flush valves
are used, lever controls are acceptable, but must be located in an
accessible location.
i.
Install toilets so seat height is at 18” (ADA allows 17” – 19”) and
centerline of toilet is 17” from wall (ADA allows 16” – 18”).
j.
Install grab bars at 34” height. (ADA allows 33” – 36”.)
k.
Install vertical grab bar as per ICC A117.1 (new requirement).
Lavatories
a.
In new construction, make all lavatories accessible.
b.
.02
c.
Install automatic faucet controls.
d.
Provide tempered water (120 degrees maximum).
Urinals
a.
Install automatic flush valves.
Showers
a.
Install roll-in showers that are 42” x 60” minimum. (ADA allows
30” x 60”.)
12