Download GasAlertMicro 5 and GasAlertMicro 5 PID
Transcript
GasAlertMicro 5 and GasAlertMicro 5 PID Attaching the Accessories Table 12. Installing the Pump Module Attaching the Accessories Installing the Pump Module The BW motorized pump module is an optional accessory for the detector. The pump module is designed to be used with the sample probe to test for gases in confined spaces. Item Description 1 Motorized pump module 2 Sensor filter 3 Detector 4 Machine screws (2) 1. To install the pump module, deactivate the detector. 2. Remove the two machine screws and the sensor cover. Remove the sensor filter from the sensor cover and insert it into the pump module. 3. Attach the pump module to the detector and replace the two machine screws. 4. Activate the detector. The detector performs the start-up self-tests and the pump test. Refer to Pump Test. 5. If the pump has been purchased separately (not included with the detector), the pump flow rate must be set prior to using the pump. Refer to Pump in the Tech Mode section. Note Figure 4. Installing the Pump Module Do not exchange pump modules between detectors. 57