Analog Input Modules Input Status Registers The second and fourth STB AVI 1270 registers in the input block of the process image are the status registers for the two analog input channels. The six LSBs in each register represent the status of each input channel: STB AVI 1270 Status Register Format 15 14 13 12 11 10 9 not used; always set to 0 8 7 6 5 4 3 2 1 0 GS (see 1) PDM (see 2) OVW (see 3) OVE (see 4) UVW (see 5) UVE (see 6) 1 2 3 4 5 6 Bit 0 is the global status (GS) bit for the input channel. It has a value of 0 when no errors have been detected. It has a value of 1 when bit 1, bit 3, and/or bit 5 has a value of 1. Bit 1 represents the status of PDM voltage on the island’s sensor bus. It has a value of 0 when no PDM voltage errors are detected. It has a value of 1 if sensor power is absent. A PDM error turns on the GS bit (bit 0). Bit 2 represents the presence or absence of an OVW. It has a value of 0 when the voltage is less than or equal to 10 V. It has a value of 1 when the voltage is greater than 10 V. An OVW in the STB AVI 1270 does not turn on the GS bit (bit 0). Bit 3 represents the presence or absence of an OVE. It has a value of 0 when the voltage is less than 10.24 V and a value of 1 when the voltage equals or exceeds 10.24 V. An OVE in the STB AVI 1270 turns on the GS bit (bit 0). Bit 4 represents the presence or absence of a UVW. It has a value of 0 when the voltage is greater than or equal to -10 V and a value of 1 when the voltage is below -10 V. A UVW in the STB AVI 1270 does not turn on the GS bit (bit 0). Bit 5 represents the presence or absence of a UVE. It has a value of 0 when the voltage is greater than -10.24 V) and a value of 1 when the voltage is less than or equal to 10.24 V). A UVE in the STB AVI 1270 turns on the GS bit (bit 0). Note: The detection of error conditions on the PDM input power connection may be delayed by as much as 15 ms from the event, depending on the sensor bus load, the system configuration and the nature of the fault. Field power faults that are local to the input module are reported immediately. 66 31007715 6/2008
Related documents
Schneider Electric Advantys STB Specifications
Schneider Electric 890USE17700 Specifications
STB analogiche
POMPES DOSEUSES MODELES EXACTUS pH-RX-CL
Schneider Electric INTERBUS Basic Specifications
PDF
Advantys STB - Schneider Electric
4076 & 4079 User Manual
Ford Mondeo Service and Repair Manual
Product Manual - Field Environmental Instruments, Inc.
Ronin – User Manual
Advantys STB - LUCKINSlive