Section 8 - Catalyst Circulation Prediction(Cat_Circ_Pred)
8.2 Detail Description
Input Table
Input
Source
Only Req’d if
Eng. Units
Description
The number of intervals to hold the last
good value. For more details see Utility
Function User’s Guide.
LGV_Num
If LGV_Num > 0, this indicates the
number of intervals the last good value
will be held.
If LGV_Num = 0, then last good value
processing is turned off.
If LGV_Num < 0, then the last good value
will be held indefinitely.
LGV_Count
Counter of number of intervals last good
value held
Last good value storage array for key
output variables
The maximum number of simultaneous
error messages that can be raised for this
function.
LGV_Values[1..4]
RetNum
Output table
The output table provides a description of the function outputs.
Output Table
Output
Eng. Units
Description
Ret_Status
Number of errors/warnings. Ret_Status is positive when the highest priority
message is an error. Ret_Status is negative when the highest priority message
is a warning. Ret_Status is zero, when there are no warnings or errors.
RetStatus[RetNum]
Array of current function return statuses. See Return Status Table below for
details.
RetMessage[RetNu
m]
Array of current Error/Warning Messages.
RetFloat[RetNum]
Array of float arguments for error messages. For internal use only.
RetString[RetNum]
Array of string arguments for error messages. For internal use only.
Value_TK_Units
TK units Mlb/hr
Calculated catalyst circulation mass flow rate
Value_User_Units
User units
Calculated catalyst circulation mass flow rate.
Note: This value must be in mass units.
Cat_To_Oil
Calculated catalyst to oil ratio
Rx_SS_To_Cat
Reactor stripping steam to catalyst ratio
52
FCCU Toolkit User’s Guide
Honeywell Inc.
5/01