Download Silver Writing4
Transcript
‘‘The Silver Sheet’’ TheSilverSheet.ElsevierBI.com Manufacturer Product NERL Diagnostics Lifesign Staph Latex Kits; Wampole II Staph Latex Test Unreactive Staph latex reagent. (Z-1110/1111-2010) NewDeal Panta Support Device and Arthrod- II esis Nail Instrumentation Tray Inability to properly align the calcaneal screw placement on a consistent basis due to a manufacturing defect of the targeting frame. (Z-0308-2011) NewDeal Qwix Stabilization Screws II The screws were etched incorrectly as “32 mm” instead of “34 mm” length. (Z-1253/1254-2010) Newport Medical Instruments e360 Ventilator II The failure of the pressure transducer results in pressure or volume alarms where P1 cannot be calibrated correctly, or in a device alert alarm associated with a P1 failure. In most cases, the failure is detected at “power on,” but failures can occur during ventilation. (Z-1617-2010) Nexcore Technology Enfant Pediatric VEP Vision Testing III System The computer-based system may lose test counts when the time in the device is changed during a changeover from standard time to daylight savings time. (Z-1437-2010) NG Instruments Mini Max Torque Drill Bit II The epoxy is flaking off of the drill bits and countersinks. (Z‑1430-2010) Nikkiso Medical Systems Aquarius System I When a certain level of fluid imbalance is detected, the Aquarius will trigger an alarm. However, users are able to override this alarm and continue therapy. By repeatedly overriding the balance alarm without solving the issue (closed clamp, kinked line, etc.), it is possible to remove too much fluid from, or replace too much fluid to, the patient. (Z-0653-2010) Ningbo Advan Electrical Co. Disposable Skin Stapler II The sterility of the staplers is questionable. (Z-1610-2010) Nissho Insurance Services Huber Needles and Infusion Sets I Non-coring needles, when inserted into an implanted port, were shown to core the silicone ports septum. (Z-0638/0640-2010.) Nova Biomedical StatStrip Glucose Test Strips II Glucose strips report low glucose results. (Z-1783-2010) Novasys Medical Renessa RF System II The instructions for use were revised to emphasize potential side effects. (Z-1404-2010) NuMED Impact Catheters II The packaging of the catheter was cracked and deteriorating. (Z-0509-2010) Ohio Medical MoblVac Portable Wound Care Pump; NPWT Small Mobile Bag II Parts were separated while in an enclosed nylon transport bag during use. (Z-1777/1778-2010) Olympus Winter & IBE Trocar Spikes II Weak weld seams. (Z-1163-2010) Optima Healthcare Hill-Rom Beds II The flexing of the junction of the sleep deck’s head and midsections can create excess pressure on the pivot pin E-ring, which could cause the E-ring to come off. (Z-2167/2170-2010) Optovue RTVue Optical Coherence Tomography II Product marketed without a 510(k). (Z-1131-2010) Organogenesis Apligraf II Product is contaminated with yeast identified as Pseudozyma Antarctica. (Z-2589-2010) Oridion Medical Various Microstream Filterline and Capnoline Products II The filterline may not be recognized by the monitor when connected. No CO2 readings will be displayed and no alarms may sound for unmonitored patients. Replacing the filterline may delay treatment. (Z-1999/2014-2010) Unauthorized photocopying is prohibited by law. Class Reason FEBRUARY 2011 | 41