Manufacturer
Product
NERL Diagnostics
Lifesign Staph Latex Kits; Wampole II
Staph Latex Test
Unreactive Staph latex reagent. (Z-1110/1111-2010)
NewDeal
Panta Support Device and Arthrod- II
esis Nail Instrumentation Tray
Inability to properly align the calcaneal screw placement on a
consistent basis due to a manufacturing defect of the targeting
frame. (Z-0308-2011)
NewDeal
Qwix Stabilization Screws
II
The screws were etched incorrectly as “32 mm” instead of
“34 mm” length. (Z-1253/1254-2010)
Newport Medical
Instruments
e360 Ventilator
II
The failure of the pressure transducer results in pressure or
volume alarms where P1 cannot be calibrated correctly, or in a
device alert alarm associated with a P1 failure. In most cases,
the failure is detected at “power on,” but failures can occur during ventilation. (Z-1617-2010)
Nexcore Technology Enfant Pediatric VEP Vision Testing III
System
The computer-based system may lose test counts when the time
in the device is changed during a changeover from standard
time to daylight savings time. (Z-1437-2010)
NG Instruments
Mini Max Torque Drill Bit
II
The epoxy is flaking off of the drill bits and countersinks.
(Z‑1430-2010)
Nikkiso Medical
Systems
Aquarius System
I
When a certain level of fluid imbalance is detected, the Aquarius
will trigger an alarm. However, users are able to override this alarm
and continue therapy. By repeatedly overriding the balance alarm
without solving the issue (closed clamp, kinked line, etc.), it is possible to remove too much fluid from, or replace too much fluid to,
the patient. (Z-0653-2010)
Ningbo Advan
­Electrical Co.
Disposable Skin Stapler
II
The sterility of the staplers is questionable. (Z-1610-2010)
Nissho Insurance
Services
Huber Needles and Infusion Sets
I
Non-coring needles, when inserted into an implanted port, were
shown to core the silicone ports septum. (Z-0638/0640-2010.)
Nova Biomedical
StatStrip Glucose Test Strips
II
Glucose strips report low glucose results. (Z-1783-2010)
Novasys Medical
Renessa RF System
II
The instructions for use were revised to emphasize potential
side effects. (Z-1404-2010)
NuMED
Impact Catheters
II
The packaging of the catheter was cracked and deteriorating.
(Z-0509-2010)
Ohio Medical
MoblVac Portable Wound Care
Pump; NPWT Small Mobile Bag
II
Parts were separated while in an enclosed nylon transport bag
during use. (Z-1777/1778-2010)
Olympus Winter & IBE Trocar Spikes
II
Weak weld seams. (Z-1163-2010)
Optima Healthcare
Hill-Rom Beds
II
The flexing of the junction of the sleep deck’s head and midsections can create excess pressure on the pivot pin E-ring, which
could cause the E-ring to come off. (Z-2167/2170-2010)
Optovue
RTVue Optical Coherence
­Tomography
II
Product marketed without a 510(k). (Z-1131-2010)
Organogenesis
Apligraf
II
Product is contaminated with yeast identified as Pseudozyma
Antarctica. (Z-2589-2010)
Oridion Medical
Various Microstream Filterline
and Capnoline Products
II
The filterline may not be recognized by the monitor when connected. No CO2 readings will be displayed and no alarms may sound for
unmonitored patients. Replacing the filterline may delay treatment.
(Z-1999/2014-2010)