Technical Manual P43 . Functional description of the input signals Pin Signal Function 11 12 13 14 15 16 CODE0 CODE1 CODE2 CODE3 CODE4 CODE5 Active at +24V. Inputs dedicated to selection (in binary code) of the welding program to be run at Start. When Start is active, the control runs the program corresponding to the binary code read (see code table on page 38). Up to 64 welding programs can be used. NB: To select program 64, all the inputs of the program code must be at logical 0V. 17 CODEP Parity code. Active at +24V. Used only on robotized lines. Is used for logical checking of the CODE0....5 inputs and depends on the setting in the Setup menu. (see code table on page 38). Warning! If it is not used, it must be disabled (see Setup programming manual). 18 CONSALD Welding consent. Input active a +24V. The welding consent is the weld enable signal; it indicates that the welding machine is ready; the welding control waits for this signal after it has sent the RICHSALD signal. The control waits until the consent signal is received Card layout: standard configuration of the jumpers J1: 2-3 JP1: Off 37