13.1.4 CAUTION Do not use the Flow-Cell Module in tests that use organic solvents such as toluene, chloroform, trichloroethane or cyclohexanone. These solvents are not compatible with the plastic components of the Flow-Cell Module, and may damage the instrument and expose the operator to harmful chemicals. Flow-Cell and Sipper Modules CUIADO No utilice el Módulo de Celda de Flujo Continuo en pruebas que usan solventes orgánicos tales como tolueno, cloroformo, tricloroetano o ciclohexanona. Estos solventes no son compatibles con los componentes plásticos del Módulo de Celda de Flujo Continuo, y podrian dañar el instrumento, exponiendo al analists a substancias peligrosas. ATENÇÃO Não use o Módulo da cubeta de fluxo em teste que use solventes orgânicos tais como tolueno, cloroformio, tricloroetano, ou ciclohexanone. Esses solventes não são compatíveis com os componentes plásticos da cubeta, e pode danificar o instrumento e expor o operador a produtos químicos perigosos. PRUDENCE Ne pas utiliser le module de cuve à circulation dans les techniques d’analyses qui utilisent des solvants organiques tels que le toluène, le chloroforme, le trichloroéthane ou la cyclohexanone. Ces solvants ne sont pas compatibles avec les composants en plastique de la cuve à circulation et peuvent endommager l’appareil en exposant l’opérateur à des produits chimiques dangereux. WARNHINWEIS Das Durchflußmodul darf nicht bei Tests verwendet werden, in denen organische Lösemittel wie Toluol, Chloroform, Trichlorethan oder Cyclohexanon benutzt werden. Diese Lösemittel sind möglicherweise mit den Kunststoffkomponenten des Durchflußmoduls nicht kompatibel und können Schäden am Gerät sowie Gesundheitsrisiken für den Laboranten verursachen. Check the modules occasionally for accumulation of film on the windows. If the windows appear dirty or hazy, soak them in a detergent bath and then rinse thoroughly with deionized water. The Flow-cell and Sipper Modules can be disassembled for cleaning if necessary. Follow cleaning instructions in the DR/4000 Optional Module Manual provided with the module. DO NOT use organic solvents such as acetone to clean any part of the Flow-cell and Sipper Modules. 13.2 Lamp Replacement 13.2.1 WARNING Disconnect power to the instrument before opening the lamp compartment. Power must remain off while changing the lamp. Tungsten (VIS) Lamp Replacement ADVERTENCIA Desconecte el instrumento de la corriente antes de abrir el compartimiento de la lámpara. La energía debe mantenerse apagada durante el reemplazo de la lámpara. ADVERTÊNCIA Desligue a energia elétrica do instrumento antes de abrir o compartimento da lâmpada. Durante a troca da lâmpada , não deverá ter energia elétrica no aparelho. ATTENTION Débrancher l’alimentation électrique de l’appareil avant d’ouvrir le compartiment de la lampe. L’alimentation doit rester coupée pendant le remplacement de la lampe. 92