Download Thermocouple Input Module User`s Manual
Transcript
CHAPTER 4 PROCEDURES AND SETTING BEFORE OPERATION 4 - 1 to 4 - 14 4.1 Procedures before Operation .......................................................................................................... 4 - 1 4.2 Handling Precautions....................................................................................................................... 4 - 2 4.3 Part Names...................................................................................................................................... 4 - 4 4.3.1 Transmission speed auto-tracking function .............................................................................. 4 - 6 4.4 Station Number Setting.................................................................................................................... 4 - 7 4.5 Module Mounting Orientation .......................................................................................................... 4 - 7 4.6 Wiring of Data Link Cable ................................................................................................................ 4 - 8 4.6.1 4.6.2 4.6.3 4.7 Wiring precautions.................................................................................................................... 4 - 8 CC-Link dedicated cable connection ........................................................................................ 4 - 8 Connection of terminating resistor ............................................................................................ 4 - 8 Wiring of Thermocouple................................................................................................................... 4 - 9 4.7.1 4.7.2 Wiring precautions.................................................................................................................... 4 - 9 Wiring with thermocouple ......................................................................................................... 4 - 9 4.8 Error Correction Using Offset/Gain Setting.................................................................................... 4 - 10 4.9 Setting of whether Pt100 Cold Junction Compensation is Enabled or Disabled ........................... 4 - 13 4.10 Maintenance and Inspection.......................................................................................................... 4 - 14 CHAPTER 5 PROGRAMMING 5 - 1 to 5 - 23 5.1 Programming Procedure.................................................................................................................. 5 - 2 5.2 Conditions of Program Examples .................................................................................................... 5 - 3 5.3 Program Example when the QCPU (Q mode) is Used................................................................... 5 - 6 5.4 Program Example when the QnACPU is Used.............................................................................. 5 - 11 5.5 Program Example when the ACPU/QCPU (A mode) is Used (Dedicated Instruction) .................. 5 - 16 5.6 Program Example when the ACPU/QCPU (A mode) is Used (FROM/TO Instructions)................ 5 - 20 CHAPTER 6 TROUBLESHOOTING 6 - 1 to 6 - 6 6.1 Checking Errors by LED Indications ................................................................................................ 6 - 1 6.2 When CH1 Disconnection Detection Flag (RXn4) to CH4 Disconnection Detection Flag (RXn7) Turns On .................................................................................................................................................... 6 - 3 6.3 When Flash Memory Read Error Flag (RXnA) Turns On ................................................................ 6 - 3 6.4 When User Range Read Error Flag (RXnB) Turns On.................................................................... 6 - 3 6.5 When Flash Memory Write Error Flag (RXnC) Turns On ................................................................ 6 - 3 6.6 When CH1 Measured Temperature Value (RWrn) to CH4 Measured Temperature Value (RWrn+3) Cannot be Read............................................................................................................................... 6 - 4 6.7 When Incorrect Values are Stored in CH1 Measured Temperature Value (RWrn) to CH4 Measured Temperature Value (RWrn+3) ......................................................................................................... 6 - 4 6.8 Troubleshooting When Data Link Execution Takes Much Time ...................................................... 6 - 4 6.9 Troubleshooting when the ERR. LED of the Master Station Flashes .............................................. 6 - 5 A-7